Data sheet, Absolute maximum ratings, Electrical specifications – GE Industrial Solutions KSTW004A2B Barracuda Series User Manual

Page 2

Advertising
background image

GE

Data Sheet

KSTW004A2B Barracuda™ Series; DC-DC Converter Power Modules

36-75Vdc Input; 12Vdc, 4.2A, 50W Output

April 1, 2013

©2012 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings

only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage (Continuous)

All

V

IN

-0.3 80 Vdc

Transient (100ms)

All

V

IN, trans

-0.3 100 Vdc

Operating Ambient Temperature

All

T

A

-40 85 °C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55 125 °C

I/O Isolation Voltage (100% factory Hi-Pot tested)

All

2250 Vdc

Electrical Specifications

Unless otherwise indicated, specifications apply at V

IN

= 48V

dc

, resistive load, and T

A

= 25°C conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

36 48

75 V

dc

Input No Load Current

All I

IN,No load

40

50

mA

(I

O

= 0A, module enabled)

Input Stand-by Current

All I

IN,stand-by

8

mA

(V

IN

= 48V

dc

, module disabled)

Maximum Input Current (V

IN

=36V

dc

, I

O

= I

O,MAX

) All

I

IN, MAX

1.6

A

dc

Inrush Transient

All

I

2

t

0.05 A

2

s

Input Reflected Ripple Current, peak-to-peak

(5Hz to 20MHz, 12μH source impedance; V

IN

=0V to 75V

dc

, I

O

= I

Omax

;

see Test configuration section)

All

30

mA

p-p

Input Ripple Rejection (120Hz)

All

60

dB

EMC, EN55022

See EMC Considerations section

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of

complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6A

(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.

Advertising