Data sheet, Feature specifications – GE Industrial Solutions KSTW004A2B Barracuda Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

KSTW004A2B Barracuda™ Series; DC-DC Converter Power Modules

36-75Vdc Input; 12Vdc, 4.2A, 50W Output

April 1, 2013

©2012 General Electric Company. All rights reserved.

Page 4

Feature Specifications

Unless otherwise indicated, specifications apply at V

IN

= 48V

dc

, resistive load, and T

A

= 25°C conditions. See Feature Descriptions for

additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current (V

on/off

= -0.7V

dc

) All

I

on/off

0.15 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.8 V

dc

Logic High Voltage (I

on/off

= 0A

dc

) All

V

on/off

2.4

TBD V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Turn-On Delay and Rise Times

(I

O

=80% of I

O, max

)

Case 1: Input power is applied for at least 1second, and then the

On/Off input is set from OFF to ON (T

delay

= on/off pin transition until

V

O

= 10% of V

O, set

)

All

T

delay

Case1

30 50 ms

Case 2: On/Off input is set to Module ON, and then input power is

applied

(T

delay

= V

IN

reaches V

IN, min

until V

O

= 10% of V

O,set

)

All

T

delay

Case2

20 50 ms

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All T

rise

5 10 ms

Output Voltage Overshoot

3 %

V

O, set

(I

O

=80% of I

O, max

, V

IN

= 48V

dc

)

Output Overvoltage Protection

1

All V

O, limit

14.0

17.0 V

dc

Input Undervoltage Lockout

Turn-on Threshold

All

V

uv/on

34 36 V

dc

Turn-off Threshold

All

V

uv/off

30 32

V

dc

Hysterisis All

V

hyst

2.0

V

dc

Note: 1.The module requires a minimum of 220 μF external output capacitor to avoid exceeding the OVP maximum limits during startup into open

loop fault conditions.