Table 2. output specifications, Electrical specifications – GE Industrial Solutions NH050x-L Series User Manual

Page 3

Advertising
background image

Data Sheet

NH033x-L and NH050x-L Series Power Modules:

March 2010

5 Vdc Input; 1.2 Vdc to 3.3 Vdc Output; 10 A and 15 A

Lineage Power

3

Electrical Specifications

(continued)

Table 2. Output Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Output Voltage Set Point

(V

I

= 5.0 V; I

O

= I

O, max

; T

A

= 25 °C)

NH0xxM-L

NH0xxS1R8-L

NH0xxG-L

NH0xxF-L

V

O, set

V

O, set

V

O, set

V

O, set

1.45
1.74
2.42
3.18

1.5
1.8
2.5
3.3

1.55
1.86
2.58
3.39

Vdc
Vdc
Vdc
Vdc

Output Voltage

(Over all operating input voltage,
resistive load, and temperature
conditions until end of life; see
Figure 35.)

NH0xxM-L

NH0xxS1R8-L

NH0xxG-L

NH0xxF-L

V

O

V

O

V

O

V

O

1.43
1.71
2.40
3.16




1.58
1.89
2.60
3.44

Vdc
Vdc
Vdc
Vdc

Output Regulation:

Line (V

I

= 4.5 V to 5.5 V)

Load (I

O

= 0 to I

O, max

)

Temperature (T

A

= 0 °C to 50 °C)

All
All
All





0.1
0.1

0.3
0.3

17

%V

O

%V

O

mV

Output Ripple and Noise Voltage

(See Figure 34.):

RMS
Peak-to-peak (5 Hz to 20 MHz)

All
All




25

100

mVrms

mVp-p

External Load Capacitance

(See Design Considerations section.)

All

0

15,000

µF

Output Current

(See Derating Curves Figures 50 and
51.)

NH033x-L
NH050x-L

I

O

I

O

0
0


10.0
15.0

A
A

Output Current-limit Inception

(V

O

= 90% of V

O, set

; T

Q32

= 80 °C;

see Feature Descriptions section.)

All

I

O

103

200

%I

O, max

Output Short-circuit Current

All

I

O

170

%I

O, max

Efficiency

(V

I

= 5.0 V; I

O

= I

O, max

; T

A

= 25 °C;

see Figure 35.)

NH033M-L

NH033S1R8-L

NH033G-L

NH033F-L

NH050M-L

NH050S1R8-L

NH050G-L

NH050F-L

η

η

η

η

η

η

η

η

80
82
87
90
77
81
85
89

83
85
89
92
81
83
87

90.5








%
%
%
%
%
%
%
%

Switching Frequency

All

265

kHz

Dynamic Response

(

ΔI

O

/

Δt = 1 A/10 µs, V

I

= 5.0 V,

T

A

= 25 °C):

Load Change from I

O

= 0% to 100% of

I

O, max

:

Peak Deviation
Settling Time (V

O

< 10% peak

deviation)

Load Change from I

O

= 100% to 0% of

I

O, max

:

Peak Deviation
Settling Time (V

O

< 10% peak

deviation)

All
All

All
All





20

200

20

200



mV

µs

mV

µs

Advertising