2 power required - cable length – maximum, 1 +5 vdc power required, 2 cable length – GE Industrial Solutions 6KCV300CTI User Manual

Page 6: 3 maximum number of drops, 3 general information, 4 blocks diagram

Advertising
background image

GEI-100275

6KCV300CTI - 11/97

5

2

Power required - Cable length – Maximum number of Drops

2.1

+5 VDC Power required

CTI converter

20mA max

Drive (RS485)

60mA max

DGF Card

60mA max

2.2

Cable length

The maximum cable length of the RS485 serial protocol allows is equal to 600 meters.
Using the CV300CTI Interface, no length of the connection cable is determined about the RS232 side
(PC side), and it is required to set the Interface directly to the PC serial output.

2.3

Maximum number of Drops

Each 6KCV300CTI can supply, in Multidrop configuration, a maximum number of 32 devices
Drives/Dgfc.
A properly sized 5V external power supply is required. A rule of thumb would be 2.5 ADC 5 V power
supply for 32 devices.

3

General information

The connection of the command DTR* to the signal DSR* is direct, without electrical interface. The

status of the signal DSR* can be used to verify the PCI-485 Interface connection to the PC.

The connection of the command RTS* to the signal CTS* is performed by mean of an electical interface

RS232. The status of the signal CTS can be used ti verify the connection and the supply of the PCI-485
interface.

4

Blocks diagram

Figure 4.1: Blocks diagram

Advertising