Data Sheet

QBVE078A0S10R4 Barracuda Series; DC-DC Converter Power Modules

45-56Vdc Input; 10.4Vdc, 78.0A, 810W Output

January 15, 2014

©2012 General Electric Company. All rights reserved.

Page 3

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Output Voltage Set-point
(V

IN

=V

IN,nom

, I

O

=30.0A, T

A

=25°C)

All V

O, set

10.35 10.40 10.45 V

dc

Output Voltage
(Over all operating input voltage (45V to 56V), resistive load, and

temperature conditions until end of life)

All w/o -P

V

O

10.08

10.71

V

dc

-P Option

V

O

9.60 10.4 11.20 V

dc

Output

Regulation

Line (V

IN

= V

IN, min

to V

IN, max

) All

0.2

% V

O, set

Load (I

O

=I

O, min

to I

O, max

)

All w/o -P

0.2

% V

O, set

Load (I

O

=I

O, min

to I

O, max

), Intentional Droop

-P Option

0.20

V

dc

Temperature (T

A

= -5ºC to +85ºC)

All

0.02 %/°C

Output Ripple and Noise on nominal output

(V

IN

=V

IN, nom

and I

O

=I

O, min

to I

O, max

) C

O

=750uF

RMS (5Hz to 20MHz bandwidth)

All

70

mV

rms

Peak-to-Peak (5Hz to 20MHz bandwidth)

All

150

mV

pk-pk

External Output Capacitance

For C

O

>4500uF, I

O

must be < 50% I

O, max

during T

rise

. All

C

O, max

0

4,500

μF

When 2 or more modules are in parallel -P

Option

0

9,000

μF

Output Current

All

I

O

0

78 A

dc

Output Current Limit Inception

All

I

O,lim

87

96 A

dc

Output Power

All

P

O

0

810 W

Efficiency
V

IN

=V

IN, nom

, T

A

=25°C

I

O

=75% I

O, max,

V

O

= V

O,set

All

η

97.0

%

I

O

=30% I

O, max

to 100% I

O, max ,

V

O

= V

O,set

All

η

96.5

%

Switching Frequency (Primary FETs)

f

sw

150 kHz

Dynamic

Load

Response

dI

O

/d

t

=1A/1s; V

in

=V

in

,

nom

; T

A

=25°C;

(Tested with a 1.0μF ceramic,, and 3200μF capacitor and
across the load.)

Load Change from I

O

= 50% to 75% of I

O,max

:

Peak Deviation
Settling Time (V

O

<10% peak deviation)

All

V

pk

t

s

__

350

700

__

mV

pk

s

Load Change from I

O

= 75% to 50% of I

O,max

:

Peak Deviation
Settling Time (V

O

<10% peak deviation)

All

V

pk

t

s

__

350
700

__

mV

pk

s

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

iso

0.01

F

Isolation Resistance

R

iso

10

MΩ

General Specifications

Parameter

Device

Symbol

Typ

Unit

Calculated Reliability Based upon Telcordia SR-332 Issue 3:
Method

I,

Case 3, (I

O

=80%I

O, max

, T

A

=40°C, Airflow = 200 LFM), 90%

confidence

All MTBF

10,401,881

Hours

All FIT

96.1

10

9

/Hours

Weight – Open Frame

59.3 (2.09)

g (oz.)

Weight – with Base plate option

73.6 (2.60)

g (oz.)