Data sheet, Feature specifications – GE Industrial Solutions QBVE078A0S10R4 Barracuda Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

QBVE078A0S10R4 Barracuda Series; DC-DC Converter Power Modules

45-56Vdc Input; 10.4Vdc, 78.0A, 810W Output

January 15, 2014

©2012 General Electric Company. All rights reserved.

Page 4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

, Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On

Logic Low Specification

On/Off Thresholds:

Remote On/Off Current – Logic Low (Vin =56V)

All

I

on/off

200

μA

Logic Low Voltage

All

V

on/off

-0.3

0.8 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.4

14.5 V

dc

Logic High maximum allowable leakage current

(V

on/off

= 2.4V)

All I

on/off

130

μA

Maximum voltage allowed on On/Off pin

All

V

on/off

14.5 V

dc

Turn-On Delay and Rise Times (I

O

=I

O, max

)

T

delay

=Time until V

O

= 10% of V

O,set

from either application of Vin

with Remote On/Off set to On (Enable with Vin); or operation of

Remote On/Off from Off to On with Vin already applied for at
least 30 milli-seconds (Enable with on/off).
* Increased T

delay

due to startup for parallel modules.

All w/o “P’

option

T

delay

,

Enable with

Vin

30 ms

All w/o “P”

option

T

delay,

Enable with

on/off

5

ms

All w/ “P’

option

T

delay

,

Enable with

Vin

40* ms

All w/ “P”

option

T

delay,

Enable with

on/off

15*

ms

T

rise

=Time for V

O

to rise from 10% to 90% of V

O,set

, For C

O

>4500uF, I

O

must be < 50% I

O, max

during T

rise

.

* Increased T

rise

when pre-bias Vo exists at startup for parallel

modules.

All w/o

“P”

option

T

rise

15

ms

All w/ “P’

option

T

rise

40*

ms

Output Overvoltage Protection

All

V

O,limit

12.0

16.0 V

dc

Overtemperature Protection

All T

ref

128

°C

(See Thermal Considerations, Fig. 16)

Input Undervoltage Lockout

Turn-on Threshold

41 44 45 V

dc

Turn-off Threshold

39 41 43 V

dc

Hysteresis

2 V

dc

Input Overvoltage Lockout

Turn-off Threshold

62

V

dc

Turn-on Threshold

60

V

dc

Advertising