Data sheet, Feature descriptions (continued) – GE Industrial Solutions QBVW033A0B Barracuda Series User Manual

Page 10

Advertising
background image

GE

Data Sheet

QBVW033A0B Barracuda Series; DC-DC Converter Power Modules

36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output

May 21, 2013

©2012 General Electric Company. All rights reserved.

Page 10

Feature Descriptions (continued)

Thermal Considerations

The thermal data presented here is based on physical

measurements taken in a wind tunnel, using automated
thermo-couple instrumentation to monitor key component
temperatures: FETs, diodes, control ICs, magnetic cores,

ceramic capacitors, opto-isolators, and module pwb
conductors, while controlling the ambient airflow rate and
temperature. For a given airflow and ambient temperature, the
module output power is increased, until one (or more) of the
components reaches its maximum derated operating
temperature, as defined in IPC-9592B. This procedure is then
repeated for a different airflow or ambient temperature until a
family of module output derating curves is obtained.

The power modules operate in a variety of thermal
environments and sufficient cooling should be provided to help
ensure reliable operation. Thermal considerations include
ambient temperature, airflow, module power dissipation, and
the need for increased reliability. A reduction in the operating
temperature of the module will result in an increase in
reliability.
Heat-dissipating components are mounted on the top side of
the module. Heat is removed by conduction, convection and

radiation to the surrounding environment. Proper cooling can
be verified by measuring the thermal reference

temperature

(TH

1

or TH

2

). Peak temperature occurs at the position indicated

in Figure 17 and 18. For reliable operation this temperature
should not exceed TH

1

=125°C or TH

2

=105°C. For extremely high

reliability you can limit this temperature to a lower value.

.

Figure 17. Location of the thermal reference temperature
TH

1

for open frame module.

Figure 18. Location of the thermal reference temperature

TH

2

for base plate module.

The output power of the module should not exceed the rated

power for the module as listed in the Ordering Information
table.
Please refer to the Application Note “Thermal Characterization

Process For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including maximum
device temperatures.

Heat Transfer via Convection

Increased airflow over the module enhances the heat transfer

via convection. The thermal derating of figure 19- 23 shows
the maximum output current that can be delivered by each
module in the indicated orientation without exceeding the

maximum TH

x

temperature versus local ambient temperature

(T

A

) for several air flow conditions.

The use of Figure 19 is shown in the following example:

Example

What is the minimum airflow necessary for a QBVW033A0B
operating at V

I

= 48 V, an output current of 20A, and a

maximum ambient temperature of 60 °C in transverse
orientation.
Solution:
Given: V

in

= 48V, I

O

= 20A, T

A

= 60 °C Determine required airflow

velocity (Use Figure 19):
Velocity = 0.5m/s (100 LFM) or greater.