Data sheet, Isolation specifications, Feature specifications – GE Industrial Solutions QBVW033A0B Barracuda Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

QBVW033A0B Barracuda Series; DC-DC Converter Power Modules

36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output

May 21, 2013

©2012 General Electric Company. All rights reserved.

Page 4

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

iso

1000

pF

Isolation Resistance

R

iso

10

MΩ

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

, Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On

Logic Low Specification

On/Off Thresholds:

Remote On/Off Current – Logic Low (Vin =100V)

All

I

on/off

280

310

μA

Logic Low Voltage

All

V

on/off

-0.3

0.8 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.0

14.5 V

dc

Logic High maximum allowable leakage current
(V

on/off

= 2.0V)

All I

on/off

10

μA

Maximum voltage allowed on On/Off pin

All

V

on/off

14.5 V

dc

Turn-On Delay and Rise Times (I

O

=I

O, max

)

T

delay

=Time until V

O

= 10% of V

O,set

from either application of Vin

with Remote On/Off set to On (Enable with Vin); or operation of
Remote On/Off from Off to On with Vin already applied for at
least 150 milli-seconds (Enable with on/off).

* Increased T

delay

due to startup for parallel modules.

All w/o P

option

T

delay

,

Enable with Vin

150 ms

All w/o P

option

T

delay,

Enable with

on/off

10

ms

All w/ P

option

T

delay

,

Enable with Vin

180* ms

All w/ P

option

T

delay,

Enable with

on/off

40*

ms

T

rise

=Time for V

O

to rise from 10% to 90% of V

O,set

, For C

O

>5000uF, I

O

must be < 50% I

O, max

during T

rise

.

* Increased T

rise

when pre-bias Vo exists at startup for

parallel modules.

All w/o P

option

T

rise

15

ms

All w/ P

option

T

rise

300*

ms

Remote Sense Range

All w/ 9

option

V

Sense

0.5 V

dc

Load Sharing Current Balance

(difference in output current across all modules with outputs in
parallel, no load to full load)

P Option

I

diff

3 A

Output Voltage Adjustment range

All w/ 9

option

V

O, set

8.1

13.2 V

dc

Output Overvoltage Protection

All w/o 9

option

V

O,limit

14.5

17.0 V

dc

All w/ 9

option

V

O,limit

V

O,set

+2.5V

V

O,set

+5.0V V

dc

Overtemperature Protection

All T

ref

140

°C

(See Feature Descriptions)
Input Undervoltage Lockout

Turn-on Threshold (Default)

33 35 36 V

dc

Turn-off Threshold (Default)

31 33 34 V

dc

Input Overvoltage Lockout

Turn-off Threshold (Default)

86

V

dc

Turn-on Threshold (Default)

76 79

V

dc

Advertising