GE Industrial Solutions QW010-015-020 Series User Manual

Page 15

Advertising
background image

Tyco Electronics Power Systems

15

Data Sheet
August 22, 2006

36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A

QW010/015/020 Series Power Modules: dc-dc Converters;

Feature Descriptions

(continued)

Overcurrent Protection

To provide protection in an output overload fault condition,
the module is equipped with internal current-limiting circuitry,
and can endure current limiting for an unlimited duration. At
the instance of current-limit inception, the module enters a
"hiccup" mode of operation, whereby it shuts down and auto-
matically attempts to restart. While the fault condition exists,
the module will remain in this mode until the fault is cleared.
The unit operates normally once the output current is
reduced back into its specified range.

Output Overvoltage Protection

The output overvoltage protection consists of circuitry that
monitors the voltage of the output terminals. If the output volt-
age exceeds the overvoltage protection threshold, the mod-
ule enters a "hiccup" mode of operation, whereby it shuts
down and automatically attempts to restart. While the fault
condition exists, the module will remain in this hiccup mode
until the overvoltage fault is cleared.

Overtemperature Protection

The output overvoltage protection consists of circuitry that
monitors the voltage on the output terminals. If the output
voltage exceeds the overvoltage protection threshold, the
module enters a "hiccup" mode of operation, whereby it shuts
down and automatically attempts to restart. While the fault
condition exists, the module will remain in this hiccup mode
until the overvoltage fault is cleared.

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will begin to
operate at an input voltage above the undervoltage lockout
turn-on threshold.

Advertising