Isolation specifications general specifications – GE Industrial Solutions QW010-015-020 Series User Manual
Page 4
Tyco Electronics Power Systems
4
Data Sheet
August 22, 2006
36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A
QW010/015/020 Series Power Modules: dc-dc Converters;
Electrical Specifications
(continued)
Isolation Specifications
General Specifications
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Response
(di/dt = 0.1 A/µs, VI = 48 V, TA = 25 °C)
Cout = 220µF Electrolytic and 1µF tantalum.
Load Change from IO = 50% to 75% of IO, max,
Peak Deviation
Settling Time (VO < 10% of peak deviation)
Load Change from IO = 50% to 25% of IO, max,
Peak Deviation
Settling Time (VO < 10% of peak deviation)
All
All
All
All
—
—
—
—
—
—
—
—
200
0.2
200
0.2
—
—
—
—
mV
ms
mV
ms
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Ciso
—
1000
—
PF
Isolation Resistance
Riso
10
—
—
M
Ω
Isolation Voltage
Viso
—
—
1500
Vdc
Parameter
Min
Typ
Max
Unit
Calculated MTBF (IO = 80% of IO, max TA = 25 °C)
Tyco RIN (Reliability Infomation Notebook) Method
3,178,000
Hours
Weight
—
27.4(0.97)
—
g (oz.)