4

Data Sheet
August 22, 2006

36 Vdc to 75 Vdc Input; 1.2 Vdc to 5.0 Vdc Output; 10 A to 20 A

QW010/015/020 Series Power Modules: dc-dc Converters;

Electrical Specifications

(continued)

Isolation Specifications

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Response
(di/dt = 0.1 A/µs, VI = 48 V, TA = 25 °C)
Cout = 220µF Electrolytic and 1µF tantalum.
Load Change from IO = 50% to 75% of IO, max,

Peak Deviation
Settling Time (VO < 10% of peak deviation)

Load Change from IO = 50% to 25% of IO, max,

Peak Deviation
Settling Time (VO < 10% of peak deviation)

All
All

All
All





200

0.2

200

0.2



mV

ms

mV

ms

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

Ciso

1000

PF

Isolation Resistance

Riso

10

M

Isolation Voltage

Viso

1500

Vdc

Parameter

Min

Typ

Max

Unit

Calculated MTBF (IO = 80% of IO, max TA = 25 °C)
Tyco RIN (Reliability Infomation Notebook) Method

3,178,000

Hours