GE

Data Sheet

KSTW002A5B Barracuda* Series; DC-DC Converter Power Modules

36-75Vdc Input; 12Vdc, 2.5A Output

September 26, 2013

©2013 General Electric Corporation. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage (Continuous)

All

V

IN

-0.3

80

Vdc

Transient (100ms)

All

V

IN, trans

-0.3

100

Vdc

Operating Ambient Temperature

All

T

A

-40

85

°C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55

125

°C

Altitude*

All

4000

m

I/O Isolation Voltage (100% factory Hi-Pot tested)

All

2250

Vdc

* For higher altitude applications, contact your GE Sales Representative for alternative conditions of use.

Electrical Specifications

Unless otherwise indicated, specifications apply at V

IN

= 48V

dc

, resistive load, and T

A

= 25°C conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

36

48

75

V

dc

Input No Load Current

All

I

IN,No load

45

mA

(V

IN

= 48V

dc

I

O

= 0A, module enabled)

Input Stand-by Current

All

I

IN,stand-by

8

mA

(V

IN

= 36 to 48V

dc

, module disabled)

Maximum Input Current (V

IN

=36V

dc

, I

O

= I

O,MAX

)

All

I

IN, MAX

1.2

A

dc

Inrush Transient

All

I

2

t

0.05

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V

IN

=36V to 75V

dc

, I

O

= I

Omax

;

see Test configuration section)

All

25

mA

p-p

Input Ripple Rejection (120Hz)

All

60

dB

EMC, EN55022

See EMC Considerations section

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of
complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 3A
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.