Data sheet, Feature specifications – GE Industrial Solutions KSTW002A5B Barracuda Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

KSTW002A5B Barracuda* Series; DC-DC Converter Power Modules

36-75Vdc Input; 12Vdc, 2.5A Output

September 26, 2013

©2013 General Electric Corporation. All rights reserved.

Page 4

Feature Specifications

Unless otherwise indicated, specifications apply at V

IN

= 48V

dc

, resistive load, and T

A

= 25°C conditions. See Feature Descriptions for

additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current (V

on/off

= -0.7V

dc

)

All

I

on/off

0.15

mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.8

V

dc

Logic High Voltage (I

on/off

= 0A

dc

)

All

V

on/off

2.4

7

V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Turn-On Delay and Rise Times

(I

O

=80% of I

O, max

)

Case 1: Input power is applied for at least 1second, and then the
On/Off input is set from OFF to ON (T

delay

= on/off pin transition until

V

O

= 10% of V

O, set

)

All

T

delay

Case1

30

50

ms

Case 2: On/Off input is set to Module ON, and then input power is

applied
(T

delay

= V

IN

reaches V

IN, min

until V

O

= 10% of V

O,set

)

All

T

delay

Case2

20

50

ms

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All

T

rise

5

10

ms

Output Voltage Overshoot

3

% V

O, set

(I

O

=80% of I

O, max

, V

IN

= 48V

dc

)

Output Overvoltage Protection (see Note1 below)

All

V

O, limit

14

17

V

dc

Input Undervoltage Lockout

Turn-on Threshold

All

V

uv/on

34

36

V

dc

Turn-off Threshold

All

V

uv/off

30

32

V

dc

Hysteresis

All

V

hyst

2.0

V

dc

Note: 1.The module requires a minimum of 220 μF external output capacitor to avoid exceeding the OVP maximum limits during startup into open
loop fault conditions.

Advertising