G-ænial Bond Technical Manual

Shear Bond Strength to Dentine
Tests performed by M. Derbanne, S. Le Goff and M. Degrange
, Paris, France
another in vitro study conducted by mathieu Derbanne, Stéphane le Goff and Michel Degrange†,
university of Paris Descartes, France, evaluated the early bond strength to dentine of G-ænial Bond
using either the self-etch or the etch-and-rinse technique.

Test set-up: Samples were prepared from human 3rd molars and split into 2 groups. In the self-etch group (SES, n=30), GBA

400 (commercially available under the brand name G-ænial Bond) was applied directly to the dentine surface as described in

the table below. In the etch-and-rinse group (E&R, n=30), the dentine surface was first etched with a 37.5% phosphoric acid gel

(Gel Etchant, Kerr) for 15 seconds prior to the application of G-ænial Bond as described in the table below. Three composites

were used in 10 samples of each group: Kalore (GC), G-ænial (GC) and Z100 (3M ESPE). The composites used were placed in

two layers of less than 2 mm each and light-cured for 20 seconds by layer (BluePhase 2 (Kerr Hawe), light intensity >1300

mW.cm-2). The samples were then stored at 37°C in water for 24 hours, after which the shear test was performed at a speed of

0.5 mm.min-1.

technique

etching Rinsing & drying air drying

application

Waiting

air drying light-curing

Self-etch

/

/

light

apply + brush 15 s

10 s

5 s

5 s

etch-and-rinse

15 s

30 s

light

apply + brush 15 s

10 s

5 s

5 s

Figure 13: early shear bond strength to dentine using the self-etch and etch-and-rinse techniques.

the chart below represents pooled results with all three tested composites. Source: adapted excerpt from Prof. m. Degrange†,

univeristy Paris Descartes, France, 2010

Statistical analysis (anOVa 1) shows that there is no significant difference (p = 0.65) between the
two methods
(self-etching and etch-and-rinse) with respect to the adhesion to dentine (Figure 13).