13 focus edition from gc – GC EUROPE Fujivest Super User Manual

Page 13

Advertising
background image

13

Focus Edition from GC

2.1.3 Liquid dilution chart

The liquid dilution chart is designed to help produce the optimal expansion value for your individual
castings and is based upon the type of alloy and size of ring used. This information is contained within
the ‘Instructions for Use’ and is based on extensive laboratory testing in combination with a complete
series of casting trials.For example here is the liquid dilution chart for GC Fujivest Premium.

Type of Alloy

Liquid / Wa-

ter ratio %

Ring size: Liquid / Water

X1 / 60 g

90 g

X3 / 150 g

X6 / 300 g

X9 / 420 g

High Precious > 70% Au

50/50

6.6 ml/6.6 ml

9.9 ml/9.9 ml

16.5 ml/16.5 ml

33 ml/33 ml

42.2 ml/42.2 ml

Semi Precious < 55% Au

60/40

8 ml/5.2 ml

11.8 ml/8 ml

20 ml/13 ml

40 ml/26 ml

55.4 ml/37 ml

Pd-base

60/40

8 ml/5.2 ml

11.8 ml/8 ml

20 ml/13 ml

40 ml/26 ml

55.4 ml/37 ml

Non-precious alloy

NiCr 75/25

10 ml/3.2 ml

15 ml/4.8 ml

25 ml/8 ml

50 ml/16 ml

55.4 ml/37 ml

CoCr 100%

13.2 ml

19.8 ml

33 ml

66 ml

92.4 ml

High Precious ceramic alloy

55/45

7.3 ml/5.9 ml

11.8 ml/8 ml

18 ml/15 ml

36 ml/30 ml

55.4 ml/37 ml

Semi Precious ceramic alloy

55/45

7.3 ml/5.9 ml

11.8 ml/8 ml

18 ml/15 ml

36 ml/30 ml

55.4 ml/37 ml

Pd-base ceramic alloy

60/40

8 ml/5.2 ml

11.8 ml/8 ml

20 ml/13 ml

40 ml/26 ml

55.4 ml/37 ml

Non-precious ceramic alloy

NiCr 72/25

10 ml/3.2 ml

15 ml/4.8 ml

25 ml/8 ml

50 ml/16 ml

69,4 ml/23 ml

CoCr 100%

13.2 ml

19.8 ml

33 ml

66 ml

92.4 ml

However because the working methods and equipment can differ between individual dental laboratories
(e.g. waxes, resins, casting liner, mixing equipment, etc.) it is possible that differing end-results may be
obtained requiring slight changes to the stated ratios (see 2.1.4).
All of the fit tests have been carried out on castings using the quick heating method (20 min setting) and
it should be noted that a longer setting time would increase the expansion.

2.1.4 Individual liquid dilution chart

When trying new alloys, alloy manufacturers or
investment materials we suggest that initially you
use the correct ratio as stated in our ‘Instructions
for Use’. It is then possible for you to judge whether
this provides the correct expansion for your needs
or a slight alteration of the dilution is needed.

We also provide a chart that can be used to
indicate the alloy type, type of work and your
personal choice of dilution ratio obtained

following your personal casting experiences.

Here it is very important to consider the information
given in sections 1.5 & 2.1.1.

Name

dental alloy

Ring type X1 Ring type X3 Ring type X6 Ring type X9

Example :

Dental alloy

XYZ

6,6 ml Exp.Liq

6,6 ml H2O

16,5 ml Exp.Liq

16,5 ml H2O

33 ml Exp.Liq

33 ml H2O

46,2 ml Exp.Liq

46,2 ml H2O

Advertising