Connect to the network, Configure director, Laser caution – Net Optics Director Pro User Manual

Page 2: For use with -48v only

Advertising
background image

© 2013 by Net Optics, Inc. Net Optics® is a registered trademark of Net Optics, Inc. Director™ and Director Pro™ are trademark of Net Optics, Inc. 800-0038-002 Rev. E 09/13

Computer with terminal

emulation software

Cisco DB9 to RJ45

Console Cable

1 0

1 0

Management

Port

Console

Port

10G

5. Set the Director IP address by typing: sysip set ipaddr=<ipaddress>

mask=<netmask> gw=<gateway> sysip commit where <ip

address> is the IP address for Director, <netmask> is the netmask, and

<gateway> is the IP address of the gateway

6. For more information on the CLI, type Help to display command

information, or see the CLI Reference manual.

7. Use Tab to auto-complete partially typed commands. Enter ? following a

command (and a space) displays the arguments for that command.
The up- and down-arrow keys access the CLI command history buffer.

To access via SSH:

1. Connect the Management port with a CAT 5e cable to a switch/hub.

To network switch or hub

4

1 0

1 0

Management

Port

Console

Port

10G

2. In a terminal window of a PC connected to the network, at the

prompt, type: ssh admin@<IP_address>.

3. Enter the password, netoptics. The Net Optics banner displays.
4. Log into Director with the default username admin and password

netoptics if no other accounts have been added.

Connect to the Network

If the Director Network Modules (DNMs) are not already installed

when you receive the unit, install them by sliding them carefully into

the DNM slots in the front panel.

To install DNMs:

1. Remove the cover plate from Slot 1 (if present) by unscrewing the two

thumbscrews.

www.netoptics.com

1

2

B

A

A

B

www.netoptics.com

Director

2

1

1

2

5

4

6

7

8

10

9

1

2

10G

1

2

Monitor

LASER

CAUTION!

Span

10

100

1000

LINK
ACT

1

2

3

4

5

6

7

8

9

10

11

12

In-Line

10

100

1000

LINK
ACT

A

A

B

B

A

A

B

B

A

A

B

B

1

2

3

4

5

6

Slot 1

Slot 2

2. Slide the DNM into Slot 1 with the DNM circuit boards riding in the

rails.

3. Push in the DNM firmly until you feel the connectors mate and the

bezel is flush with the front panel.

4. Secure the DNM with the two captured thumbscrews.
5. Repeat for Slot 2 if installing two DNMs.
Warning! Use caution when installing the DNM into the chassis
to prevent damage to any components on the bottom side.

Connect to DC Power

For DC powered models, you must supply your own power cables. DC

power cables must have a wire gauge of at least 16 AWG and a 72 VDC,

6A rating. You need a Phillips screwdriver to complete installation. If

present, remove the protective covers from the DC power terminal

blocks. Use the Phillips screwdriver to tighten the connections.
Caution: Always connect the earth electrical grounds first, and keep the

earth grounds connected whenever you are working on the device.

For use with -48V Only

-

+

For use with -48V Only

-

+

Management

Port

Console

Port

10G

1 0

1 0

Management

Port

Console

Port

10G

Earth

Ground

-48VDC

Return

-48VDC

Return

Power Source 1

Power Source 2

Independent Power Sources

1. Connect an earth ground lead to the terminal labeled with the ground

symbol ( ), which is the left-most terminal, on both DC power terminal
blocks on the rear of the chassis.

2. Connect Power Source 1 DC power cables to the DC power terminal

blocks on the rear panel.

3. Connect the negative (– 48VDC) side of the cable to a terminal labeled

with the minus symbol (–), and the positive (0V) side of the cable to the
terminal labeled with the plus symbol (+). The negative (minus symbol)
terminal is in the center, and the plus terminal is to the right.

4. Connect Power Source 2 DC power cables to the DC power terminal

blocks on the rear panel.

5. Connect the negative (– 48VDC) side of the cable to the terminal

labeled with the minus symbol (–), and the positive (0V) side of the
cable to the terminal labeled with the plus symbol (+).

6. Carefully connect the other two – 48VDC ends of the DC power cables

to two negative (– 48VDC) power sources.

Caution: If possible, turn off the power to the power sources while you

are making the following connections.
7. Connect the other two + 48VDC ends of the DC power cables to two

positive (+ 48VDC) power sources.

Note: Be sure to connect the positive side of a cable to the positive side

of the power source, and the negative side of the power cable to the

negative side of the power source.

Configure Director

All configuration options, status, and statistics are configurable and

viewable using the command-line interface (CLI). To get started with the

Director, connect a console to the Director device console port interface

to access the CLI. Through the local CLI, set the Management port IP

address to enable remote access to the device.

To access the Command Line Interface:

1. Connect a PC with terminal emulation software to the Director device

Console port using the supplied DB9 to RJ45 cable.

2. Launch the terminal emulation software such as

HyperTerminal or minicom and set the communication parameters:

115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.

3. At the login prompt, type admin, and at the password prompt, type

netoptics.

4. Enter a new password for the admin account.