Connect to monitoring devices, Check the installation, Create a filter – Net Optics Director Pro User Manual

Page 3: Daisy chain director units, Laser caution, Caution

Advertising
background image

© 2013 by Net Optics, Inc. Net Optics® is a registered trademark of Net Optics, Inc. Director™ and Director Pro™ are trademark of Net Optics, Inc. 800-0038-002 Rev. E 09/13

To connect Director to a Span port on your network:

1. Connect any network port on a Span DNM to an

appropriate network cable.

www.netoptics.com

Director

2

1

1

2

5

4

6

7

8

10

9

1

2

10G

1

2

Monitor

LASER

CAUTION!

Span

10

100

1000

LINK
ACT

10

100

1000

LINK
ACT

1

2

3

4

5

6

7

8

9

10

11

12

In-Line

A

A

B

B

A

A

B

B

A

A

B

B

1

2

3

4

5

6

To Span port

2. Connect the other end of the cable to a Span port on a network

switch.

To connect Director in-line to your network:

1. Connect any “A” network port on an in-line DNM to a network

cable.

2. Connect the other end to a network link you are tapping.
3. Connect the corresponding “B” network port to an appropriate

network cable. In-line port pairs are located side-by-side in the
DNMs.

4. Connect the other end to the other side of the network link you

are tapping.

www.netoptics.com

Director

2

1

1

2

5

4

6

7

8

10

9

1

2

10G

1

2

Monitor

LASER

CAUTION!

Span

10

100

1000

LINK
ACT

10

100

1000

LINK
ACT

1

2

3

4

5

6

7

8

9

10

11

12

In-Line

A

A

B

B

A

A

B

B

A

A

B

B

1

2

3

4

5

6

To network switch A

To network switch B

Connect to Monitoring Devices

1. Remove the temporary plug from the monitor slot and insert the

SFP module until it clicks into place.

2. Connect the cable supplied with the SFP module to the SFP port.
3. Connect the other end of the cable to the monitoring device.

www.netoptics.com

Director

2

1

1

2

5

4

6

7

8

10

9

1

2

10G

1

2

Monitor

LASER

CAUTION!

Span

10

100

1000

LINK
ACT

1

2

3

4

5

6

7

8

9

10

11

12

In-Line

10

100

1000

LINK
ACT

A

A

B

B

A

A

B

B

A

A

B

B

1

2

3

4

5

6

To monitoring device

Connect to 10 Gigabit Ports

Each of the 10 Gigabit ports (two on the front of the chassis of

DIR-7400 and DIR-6400p, and two on the rear of DIR-7400 and DIR-

5400, one rear port for DIR-6400p), can be connected as network

or monitor ports. These ports require XFP modules (ordered and

shipped separately). The function of the port, as network or monitor, is

determined by how you configure the port.

Check the Installation

After you have made your connections to the Director, verify that it

is functioning correctly:
• Check that the power LEDs are illuminated.
• Check the link LEDs for each of the connected ports to verify that

the links are connected and traffic is present.

Create a Filter

To view traffic on monitor ports, you must define one or more filters.

For example, create a filter that:
• Aggregates traffic received on network ports 1 to 5 and 7
• Drops any traffic originating from 10.1.1.1
• Forwards only Layer 4 traffic going to Port 80
• Regenerates it to monitor ports 1 and 2
To create the filter, enter the three following commands using the

CLI:
Net Optics> filter add in_ports=n1.1-n1.5,n1.7 ip4_src=10.1.1.1

action=drop

Net Optics> filter add in_ports=n1.1-n1.5,n1.7 l4_dst_port=80

action=redir redir_ports=m.1-m.2

Net Optics> filter commit
For more information, see the Director and Director Pro User Guide

included on the Director CD.

Daisy Chain Director Units

Daisy chaining (or stacking) is the process of creating a single,

logical multi-unit system from many systems.

• DIR-7400, DIR-5400 and DIR-6400p support daisy chaining.

• DIR-6400p can only be used as a master unit and/or the slave unit

of the chain.

• Up to ten units can be daisy chained in one multi-unit system.

• All units in the system must be running the same version of the

Director software.

• All units must have their own IP address and be connected to the

network.

• All units must be interconnected in a daisy chain configuration by

cabling port t2.2 (rear right 10G port) of the Master unit to port

t2.1 (rear left 10G port) on the next unit. Ports t2.1 on the first unit

in the daisy chain and t2.2 in the last unit are unused (they cannot

be used as network or monitor ports.)

• Once systems are operating in a daisy chain, all management

(CLI, Web Manager, and System Manager) functions operate

through the master unit. If a remote unit’s device management

functions are accessed through the remote unit’s serial port or

management IP address, the results are unpredictable.

• All units are assigned Unit ID (UID) numbers consecutively

starting with 1. The UID 1 is at the beginning of the daisy chain

and is the master unit; the rest are slave or remote units.

Advertising