Other features, Wiring diagrams troubleshooting – Comfort Stat CP1820 User Manual

Page 2

Advertising
background image

H OLD 

CLEAR 

HOLD 

CLEAR 

DAY 

HOUR 

HO LD 

CLEAR 

HO LD 

CLEAR 

FOR WINTER 

NUMBER 

PROGRAM 

PROGRAM 

PROGRAM 

PROGRAM 

MONDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TUESDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

WEDNESD 
AY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

THURSDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

FRIDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

SATURDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

SUNDAY 

TIME 

TEMP 

TIME 

TEMP 

TIME 

TEMP 

TIME 

TEMP 

FOR SUMMER 

NUMBER 

PROGRAM 

PROGRAM 

PROGRAM 

PROGRAM 

MONDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TUESDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

WEDNESD 
AY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

THURSDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

FRIDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

SATURDAY 

TIME 

TEMP 

TIME 

TEMP 

TIME 

TEMP 

TIME 

TEMP 

SUNDAY 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

TIME 
TEMP 

Programming Your Thermostat 

Your thermostat can be programmed in two different ways. 

1. Auto­program method                                    2. Manual method 

Before programming, position the HEAT/OFF/COOL selector to be programmed. 

Auto Programming 

Our thermostat is pre­programmed guidelines for energy efficiency. Note that it is easier 

to modify these programs than to programs than to program the thermostat manually. 

■ Press once. During Auto Programming, the display 

will change as shown. 

■ The thermostat will be programmed for all 7 days of 

the week as shown below. 

Temperature in ˚F/℃ 

Program Number 

Time 

Heat 

Standard 

6:00am 

68 ˚F    (20℃) 

78 ˚F    (26℃) 

8:00am 

60 ˚F    (16℃) 

85 ˚F    (29℃) 

4:00am 

68 ˚F    (20℃) 

78 ˚F    (26℃) 

10:00am 

60 ˚F    (16℃) 

85 ˚F    (29℃) 

■ Refer to Manual Programming entering or changing the programs. 

Manual method 

In  this  method,  each  program  is  inserted  according  to  your  personal  programming 

schedule. 

Familiarize yourself with manual programming. The following example demonstrates the 

manual  programming  method.  You  can  program  or change the  program  of  weekdays, 

weekends, or individual days. 

NOTE:1) The program time is set in increments of 15 minutes. 

2) The program temperature is set in increments of 1℉. 

3) When setting PM time, make sure the “PM” indicator appears on the display. 

Weekday Programs 

Press                                                                                                          Display Reads 

■ Normal display of time, temperature, 

and day of the week. 

Step 1 

■ Selects days Mon to Fir for same set of 4 

programs each day. 

Step 2 

■ Program indicator(1) is displayed. 
■ 68℉ is displayed. 

■ Mon to Fir is displayed. 

Step 3 

■ Press and hold until 6:00 is displayed. 
■ Note AM/PM 

Step 4 

■ Press once to change temperature to 69℉. 
■ Weekday program 1 is complete. 
■ Press PROG to move to program 2,3, and 4 

and follow the same steps. 

Use                                                                to insert or change time and temperature 

of other programs. 

■ Selects weekend days Sat, Sun for same 

set of 4 programs each weekend day. 

■ Follow steps 2­4 to enter programs. 

Similar to weekday programming. 

to insert weekend programs. 

Individual Day Programming 

To program for each individual day separately by a different set of programs, first select 

day by displaying the day of program, then insert the desired times and temperatures. 

Press                                                                                                                Display Reads 

■ Mon to Fir are selected. Mon to Fir will have 

Same programs. 

■ Sat to Sun will have 

Same programs. 

■ Mon is selected, program for Mon only. 

Use                                                                          to enter programs for Monday. 

Similarly                                                                  Tue to Sun can be selected. 

Display the day to be programmed and use 

to enter programs. 

NOTE:  Another  approach  to  programming is  to  first  program  all  weekdays  Mon 

through  Fir  and  Sat  and  Sun  as  same  programs.  Then,  display  and  change  the 

programs of only those days which will have different programs. 

Reviewing Programs 

You  may  want  to  review  the  programs  to  see  that  the  settings  are  compatible  with  your 
lifestyle. 

■ Normal display of current time, day of week 

temperature, and day of week. 

■ 1st weekday program is displayed. 
■ Program indicator(1) appears. 
■ Mon to Fri indication appears. 

■Continue pressing 

to view each day. 

■Continue pressing 

to view each period. 

If  you  are  armchair  programming  the  thermostat,  before  you  mount  the  face  of  the 

thermostat, turn the system selector to the OFF position. 

Temporary Manual Override 
To temporarily change the current set temperature without affecting your program: 

Press 

and                  to  change  to  your  desired  new 

temperature.

■Press to RUN to normal mode, or wait 15 seconds for it 

to return automatically. 

■The current program number will flash to signify the Temporary Override. At 

the  next  program  change,  the  Temporary  Override,  and  the  next  program 

temperature becomes the set point temperature. 

To end the Temporary Manual Override: 

■Press and wait for HOLD to display on the lcd. 
■Press HOLD key. This will return the set temperature to the current program 

set temperature. 

Permanent Override or a Designated Day Override 

To hold your Manual Override for vacation or Until a Designated 

Day 

■ Press to make the current program temperature 

the  HOLD  temperature.  HOLD  will  be  displayed  on 

the LCD, and the Program number will disappear. 

■ Follow the Temporary Manual Override instructions above to change the 

Permanent Manual Override temperature. 

■  You  can confirm  the  held  set  temperature  by  pressing  for  less  than  1 

second. 

■ Press again. Hold day will be displayed on the lcd 

and the clock will disappear 

■Press  Day  key  to  add  override  days. 

Press Hour key to reduce override days 

■ Follow the Temporary a Designated Day 

Override  instructions  above  to  change  the  Permanent  Manual 

Override 

temperature. 

To end Override: 

Under  Permanent  Override  Press  hold/return  key  twice.  Under  a  Designated  Day 

Override press the hold once. The thermostat will return to the current program, and the 

HOLD display will be canceled. 

Other Features 

12Hr. / 24 Hr. Time Format 

Your thermostat is set from the factory in normal 12 (AM/PM) time format. To change to 

24 hour (military) time, press                            during time and day setting mode to toggle 

between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed 

in 24 hour mode. Both the current time and all programs will automatically change to 

the selected format. 

Backlighting 

Your  thermostat  has  an  electroluminescent  lamp  that  backlights  the  display  for  easy 

viewing in the dark. 

When any key is pressed the display is illuminated. 

The  display  will  remain  illuminated  for  8  seconds  after  the  last  key  is  pressed.  This 

allows the light to stay on if you need to operate several keys. 

Note: If the thermostat is in Low Battery warning condition, the backlight will not operate. 

Replace with 2 new AA alkaline batteries to restore the Backlight function. 

Filter Monitor 

Your thermostat  also keeps  a  record  of the  number  of  hours  your 

filter has been in use. To maximize your system’s performance and 

energy efficiency, change or clear your filter regularly. 

When the total system run time for heat and cool reaches 400 hours, 

you need clean or change your system’s filter, “FILT” will continue to 

flash until the counter is set back to zero. 

■  Press to review total filter usage. The display will blink “FILT” 

Then show the filter Monitor counter. After 15 seconds, the display 

will return to normal mode, or you can hit RUN to exit immediately. 

The Filter Monitor will display up to 999 hours and 59 minutes of usage. In this example, 

the counter is at 410 Hours, 26 minutes. 

■  To reset the Filter Monitor counter, depress FILTER for 3 seconds.  The display will 

blink, and The counter will be reset to zero. 

Auto Recovery 

Auto  Recovery  calculates  how  early  to  turn  you  system  back  on,  so  that  the  room 

temperature  is  already  comfortable  by  the  start  of  the  comfort 

temperature  program  period.  Auto  Recovery  work’s  in  both  Heat 

and Cool modes. 

■When the thermostat is in  Auto Recovery mode, the display will 

alternate “RECO” with time, and the program indicator will flash. 

■Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to 

disable. 

■Auto Recovery will not operate if Permanent hold or Temporary hold is in operation. 

■Auto  Recovery  can  be  canceled  manually  if  HOLD  is  pressed  during  the  recovery 

process. 

■Auto Recovery will be canceled and change to next period. 

Details of Auto Recovery Operation: 

■  Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to 

this position. 

■  Auto Recovery will not operate if Permanent hold or Temporary hold is in operation. 

■  Auto Recovery can  be  canceled  manually  if  HOLD  is  pressed  during  the  recovery 

process. If a recovery process is canceled manually then the recovery process will not 

start again until the next program period starts (an exception is that if time or program is 

changed then the thermostat will check Auto Recovery conditions immediately). 

Error Mode 

If  the  thermostat  is  unable  to  control  your  system  due  to  an 

unexpected battery problem, the thermostat will enter Error Mode. 

In  this  condition,  the  thermostat  flashes  “E1”or  “E2”on  the  LCD 

display,  and  shuts  off  your  system.  To  correct  this  problem, 

replace the batteries with 2 new AA alkaline batteries, even if you 

have recently replaced them. Move the battery out hold any key 

then  place  the  battery  again.  You  will  need  to  reprogram  your 

thermostat and confirm normal operation. 

Lcd display 

information 

Lcd display 

information 

E1 

Sensor Error 

E2 

System switch 

Low Battery Warning 

Your thermostat has a two­stage lower battery warning system. When the batteries are 
first detected to be weak, the first stage low battery warning is indicated 

by  “BATT”  flashing  on  the  LCD  display.  At  your  earliest 
convenience,  you  need  to  replace  the  batteries  with  2  new  AA 

alkaline batteries. 
When  the  batteries  become  too  weak  for  normal  operation,  the 

thermostat  enters  the  second  stage  low  battery  warning  which 
shuts down the thermostat. In this condition, “BATT” flashes alone 

on the display, and the thermostat will turn your system Off. Your 
system will remain shut­off until the batteries are replaced. 

NOTE: The thermostat will still keep the current Set Temperature and Filter run time in 
memory until new batteries are installed. After confirming that new batteries have been 

inserted, the thermostat will return to normal operation. 

Wiring Diagrams 

Troubleshooting 

Problem 

Solution 

SCRAMBLED OR DOUBLE DISPLAY 1. Remove clear mylar sticker. 

(numbers over numbers) 

NO DISPLAY 

1.Check battery connections and batteries. 
2.Move  the  battery  out,  and then  hold  any key  to 

release  the  rest  energy.  Then  place  the  battery 
again. 

ENTIRE DISPLAY DIMS 

1.Replace batteries. 

PROGRAM DOES NOT CHANGE 

AT YOUR 

1.Check that time is set properly to “AM” or “PM” 

DESIRED SETTING 

2.Check that thermostat is not in “HOLD” mode. 
3.Check for correct day setting. 

AUTO/FAN DOES NOT COME ON 

1.Move HG/HE system selector to opposite 

Position. 

HEATING OR COOLING DOES NOT GO ON OR OFF 

1.Check that function switch is in correct 

position (“HEAT” or “COOL”). 

2.There  may  be  as  much  as  20  seconds  delay 

before the system turns on – wait and check . 

3.Check your circuit breaks and switches to ensure 

there is power to the system. 

4.Replace batteries. 
5.Make  sure  your  furnace  blower  door  is  closed 

properly. 

6.If your system only uses 4­wires, be sure the 

jumper wire is installed between the RC and RH 
terminals. 

ERRATIC DISPLAY 

1.Move the battery out, and then hold any key to 

release the rest energy. Then place the battery 
again. 

IF UNIT CONTINUES TO OPERATE  1.Replace unit. 
IN OFF POSITION 

THERMOSTAT PERMANENTLY 

1.Replace unit. 

READS “HI”, “LO”, OR “E1”,E2.. 

If you experience any other problems, call us for technical assistance. 

The service number is 1­866­591­9898 

HOUR 

DAY 

PROG 

PROG 

DAY 

PROG 

HOUR 

MIN 

DAY 

PROG 

DAY 

PROG 

DAY 

PROG 

AUTO 
PROG 

DAY 

PROG 

HOUR 

MIN 

DAY 

PROG 

HOUR 

MIN 

DAY 

PROG 

R U N 

12/24 

HO URS 

HOUR 

MIN 

PROG 

DAY 

PROG 

PROG 

RC 

RH 

THERMOSTAT 

RC 

RH 

RC 

RH 

THERMOSTAT 

THERMOSTAT 

RC 

RH 

THERMOSTAT 

RC 

RH 

THERMOSTAT 

120V 
AC 

120V 
AC 

120V 
AC 

120V 
AC 

120V 
AC 

AC24V 

AC24V 

AC24V 

AC24V 

AC24V

Advertising