AVSL 652.000 IMS150/300/600/1000/1500/2500 User Manual

Page 7

Advertising
background image

User Manual

when in use, please discontinue use immediately and contact technician or retailer

-

This inverter is design to be maintenance free, but requires occasional attention as dust may build
up after period of time. To clean dust off, please switch off power from inverter and unplug AC
plug. Carefully clean unit with a dry cloth. Do not use a wet cloth or cleaner

-

Check and tighten the DC input terminal on regular basis, as if the inverter is stored in an
environment with a lot of vibration (eg in a vehicle) it may cause the hand screw to become loose

-

Keep out of reach of children

PROTECTION FEATURES:
This inverter has several protection features designed to protect the unit from failure and also to ensure
the safety of user if the unit does fail.
PROTECTION FEATURES

INDICATION
BUZZER

FAULT LED

Low input power protection warning

Sound 2 times every 8 sec

Flash 2 times every 8 sec

Low input power protection critical

Sound 3 times every 8 sec

Flash 3 times every 8 sec

Input over power protection

Sound 4 times every 8 sec

Flash 4 times every 8 sec

Over heat protection

Sound 5 times every 8 sec

Flash 5 times every 8 sec

Short circuit protection

N/A

Constant flash

Over load protection

N/A

Constant flash


Low input power protection warning
– the input power is below 10.8V± 0.2V for 12V input inverter

and 21.6V± 0.4V for 24V input inverter. This indicates the power bank is running low or DC power supply
is insufficient, requires charging or boost of DC power supply.


Low input power protection critical
– the input power is below 10.2V± 0.2V for 12V input inverter and

20.4V± 0.4V for 24V input inverter. This indicates the power bank or DC power supply is critically low, to
protect the battery and dc power supply from over drained, inverter will switch off AC output.

Input over power protection - the input power is over 15.5.2V± 0.2V for 12V input inverter and
31V± 0.4V for 24V input inverter, the inverter will shut the output off to stop inverter from damage by the

extra input power.

Over heat protection – when inner temperature exceeds 45°C, temperature controlled fan will
automatically switch on to try to cool down the unit. If unit can not be cooled down due to high ambient

temperature or any other reason and inner temperature reaches 75°C, the inverter will automatically shut
down the output to stop inner temperature creeping higher to cause damage to components.


Short circuit protection
– in case of short circuit occurs, AC output will be switched off to eliminate

shock hazard to user.

Over load protection
– in case of overload occurs, AC output will be automatically switched off to

protect inverter from damage.