Absolute maximum ratings, Recommended operating conditions – Diodes 74AUP1G02 User Manual

Page 3

Advertising
background image

74AUP1G02

Document number: DS35146 Rev. 2- 2

3 of 14

www.diodes.com

July 2013

© Diodes Incorporated

74AUP1G02


Absolute Maximum Ratings

(Note 4) (@T

A

= +25°C, unless otherwise specified.)

Symbol

Parameter

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

kV

ESD CDM

Charged Device Model ESD Protection

1

kV

V

CC

Supply Voltage Range

-0.5 to +4.6

V

V

I

Input Voltage Range

-0.5 to +4.6

V

V

o

Voltage applied to output in high or low state

-0.5 to V

CC

+0.5

V

I

IK

Input Clamp Current V

I

< 0

50

mA

I

OK

Output Clamp Current (V

O

< 0 )

50

mA

I

O

Continuous output current (V

O

= 0 to V

CC

)

±20 mA

I

CC

Continuous current through V

CC

50

mA

I

GND

Continuous current through GND

-50

mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

Note:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should be

within recommend values.




Recommended Operating Conditions

(Note 5) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Min

Max

Unit

V

CC

Operating Voltage

0.8 3.6 V

V

I

Input Voltage

0 3.6

V

V

O

Output Voltage

0

V

CC

V

I

OH

High-Level Output Current

V

CC

= 0.8V

-20

µA

V

CC

= 1.1V

-1.1

mA

V

CC

= 1.4V

-1.7

V

CC

= 1.65V

-1.9

V

CC

= 2.3V

-3.1

V

CC

= 3.0V

-4

I

OL

Low-Level Output Current

V

CC

= 0.8V

20

uA

V

CC

= 1.1V

1.1

mA

V

CC

= 1.4V

1.7

V

CC

= 1.65V

1.9

V

CC

= 2.3V

3.1

V

CC

= 3.0V

4

Δt/ΔV

Input Transition Rise or Fall Rate

V

CC

= 0.8V to 3.6V

200

ns/V

T

A

Operating Free-Air Temperature

-40 +125

°C

Note:

5. Unused inputs should be held at V

CC

or Ground.


















Advertising