Installation, Operating and Maintenance Instruction

Model

MP, MPA, MPAI


MP 100-english

page 81

Revision 04

Article No 771074011

Issue 11/2011

pic 4 - Alignment of coupling with gauge and ruler

pic 5 - Adjustment using dial gauge

Control alignment of coupling again in operation
warm condition and on system pressure (if
available) and correct, if necessary. Pay
attention to chapter 6 beforehand! It must be
possible to turn the unit easily and harmoniously
by hand.

Improper alignment of the unit can lead to
damages at coupling and unit!

Mount coupling guard after alignment and
before start-up.

5.3.3 Permitted displacement for flexible couplings

Coupling size

H

80

F

K

H

95

F

K

H

11

0F

K

B

12

5K

F

H

12

5F

K

B

14

0F

K

H

14

0F

K

B

16

0F

K

H

16

0F

K

B

18

0F

K

H

18

0F

K

B

20

0F

K

H

20

0F

K

B

22

5F

K

H

22

5F

K

Outer diameter of coupling
[mm]

80 95 110 125 140 160 180 200 225

Axial distance S

S

max

3

6

S

min

2

Max. radial displacement
∆K

r

0,1

0,2

Max. angular
displacement
S

max

. S

min

∆K

w

= S

max

- S

min

0,1

0,2

0,3

The given values ∆K

r

and ∆K

w

apply for 1500 min

-1

.

For all other speeds the following applies:

K

w

. S

n

bzw. ∆K

r

. S

n

5.3.4 Coupling Guard

Acc. to accident prevention regulations the
pump must only be operated with coupling
guard.

Care has to be taken, that the used coupling
guard consists of non-sparking material.


Parts:

Assembly:

ruler

gauge

ruler

speed n [min

-1

]

sp

ee

d

fa

ct

or

S

n