Installation check list, Caution – John Wood Superflue Power Vent (before FVIR technology) User Manual

Page 12

Advertising
background image

-10-

1. Has the gas piping been leak tested?

2. Is the heater connected to the correct gas

supply as shown on the rating plate (Natural
Gas / Propane)?

3. Is the clearance between the heater and com-

bustible construction as per specifications?

4. Does the area around the heater have ade-

quate ventilation?

5. Does the gas piping conform with the recom-

mendations of your Gas Utility Company?

6. Is the water piping correctly connected and

are there no leaks?

7. Is the water heater filled with water?

8. Is the water supply valve open?

9. Is the vent pipe installed properly and are hor-

izontal runs properly supported?

10. Is the draft hood air intake opening unob-

structed?

11. Is the T&P valve installed, and the drain pipe

from the T&P valve unobstructed?

12. Is a drain pan installed (if required) with a

proper overflow pipe, directed to a drain?

13. Have you taken steps to prevent water dam-

age in case of leaks?

14. Is the electric supply a 120V, electrically

grounded, 15A circuit?

Check Here

Check Here

Installation Check List

If the answer to all of the questions above is “yes”, proceed with lighting the heater.

140° MAX. DIAL

160° MAX. DIAL

GAS CONTROL

SWITCH

QUICK CONNECTS

MAIN AND IGNITOR

TERMINAL BLOCK

BLOWER AND JUNCTION BOX

SAFETY

COVER

INLET PRES-

SURE PORT

GAS INLET

1/2” NPT

MANIFOLD

CONNECTION

MANIFOLD

PRESSURE

PORT

LED INDICA-

TOR

MANIFOLD PRESSURE

ADJUSTMENT

(REMOVE DIAL

FOR ACCESS)

GAS CONTROL - VIEW OF ELECTRICAL

CONNECTIONS, WITH COVER REMOVED

GAS CONTROL - VIEWED FROM GAS INLET

WITH TEMPERATURE DIAL REMOVED

Figure 11

Figure 10

IF YOUR WATER HEATER IS EQUIPPED
WITH A CAST IRON BURNER, PERFORM
THE FOLLOWING INSPECTION BEFORE
STARTING THE WATER HEATER.

1. Remove outer door from casing.
2. Check for insulation blockage (See arrows)
3. If insulation is blocking primary air, remove, so

that no insulation is in the area.

4. Check for fully open air shutter, as shown,

ensure no insulation has become lodged in burn-
er venturi.

5. Refer to installation manual “ Burner

Maintenance” for cast iron burners, for further
information.

CAUTION

NO INSULATION SHOULD BLOCK PRIMARY AIR
OPENING