Maintenance and service, Unit draining and filter cleaning – John Wood Takagi - 710 User Manual

Page 22

Advertising
background image

22

• If you desire a hot water temperature other than the 8

preset settings, please purchase the optional tempera-
ture remote controller (part No. TM-RE30).

• With this optional remote controller you can set the tem-

perature from 38°C to 85°C (100ºF to 185ºF) with various
increments.

• Please read the instructions carefully prior to installing

the remote controller, as failure to do so could damage
the temperature controller and/or the water heater, which
will void the warranty.

Turn off the power supply to the heater
before changing the DIPswitch settings.
Only change the switches with the dark
squares. The dark squares indicate
which direction the DIPswitch should be
set to.
DO NOT set to 85°C (185°F) if you
use your water heater in a recirculation
system. This will cause damage to the
heater and void the warranty.

7-Seg LED

Left bank of
DIPswitches

Right bank of
DIPswitches

To change DIPswitch settings for temperatures, locate the
left bank of DIPswitches the lower of 7-Seg LED. DO NOT
adjust the right bank of DIPswitches.

Temperature Settings (Left bank of DIPswitches)

100 ºF

(38 ºC)

115 ºF

(46 ºC)

120 ºF

(49 ºC)
Default

135 ºF

(57 ºC)

145 ºF

(63 ºC)

155 ºF

(68 ºC)

165 ºF

(74 ºC)

185 ºF

(85 ºC)

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

8

7

6

5

4

3

2

1

TMP1
TMP2
TMP3

MODE

DIRE

OUT

D-PRT

MST

ON

MAINTENANCE AND SERVICE

WARNING

Turn off the electrical power supply and
close the manual gas control valve and the
manual water control valve before servic-
ing.

• Clean the cold-water inlet filter. (Refer to diagram

below)

• Be sure that all openings for combustion and ventilation

air are not blocked.

• Check that the exhaust vent pipe is not blocked.
• Check the gas pressure.

• Keep the area around the water heater clear. Remove

any combustible materials, gasoline or any flammable
vapors and liquids.

The manufacturer recommends having the unit checked
once a year or as necessary by a licensed technician.
If repairs are needed, any repairs should be done by a
licensed technician.

Unit Draining And Filter Cleaning

Drain

Plug

Water

Valve

Drain Plug

with Filter

Gas

Valve

Close the manual gas shut off valve.
Turn off power to the unit, and then turn on again.
Wait 30 seconds, and then turn off power to the unit, yet
again.
Close the water shut off valve.
Open all hot water taps in the house. When the residual
water flow has ceased, close all hot water taps.
Have a bucket or pan to catch the water from the unit’s
drain plugs. Unscrew the drain plugs to drain all the
water out of the unit.
Wait a few minutes to ensure all water has completely
drained from unit.
Clean the filter: Check the water filter located within the
cold inlet. With a tiny brush, clean the water filter of any
debris which may have accumulated and reinsert the fil-
ter back into the cold water inlet.

Securely screw the drain plugs back into place. Hand-
tighten only.

1.
2.
3.

4.
5.

6.

7.

8.

9.

Advertising