Troubleshooting – Error Codes

The 910 units are self diagnostic for safety and conve-
nience when troubleshooting.
If there is a problem with the installation or the unit, it will
display a numerical error code on the remote controller
(if installed) or on the 7-Seg LED of the central computer
board and section computer board to communicate the
source of the problem.
Consult the following chart for the cause of each error
code.
The top red lamp will flash when the right combustion
section has an error code.
The mid red lamp will flash when the left combustion sec-
tion has an error code.

Upper bank of
DIPswitches

Lower bank of
DIPswitches

7-Seg
LED

Top red
lamp

Mid red
lamp

Remote controller (Optional)

Error

Code

Malfunction description

031

Dipswitch Setting fault

101

Warning for 991 Error Code

111

Ignition Failure

121

Flame blows out

311

Output Thermistor Failure

321

Inlet Thermistor Failure

331

Mixing Thermistor Failure

391

Air-fuel Ratio Rod Failure

441

Flow Sensor Failure

510

Abnormal Main Gas Valve

551

Abnormal Gas Solenoid Valve

611

Fan Motor Fault

631

Abnormal External Pump

651

Water Control Valve Fault (Flow Adjustment
function)

661

Water Control Valve Fault (Bypass function)

681

Abnormal External Fan motor

701

Computer board Fault

721

False Flame Detection

741

Miscommunication between water heater and
remote controller

761

Miscommunication in Easy-Link OR Multi-unit
system

991

Abnormal burning

Single Unit
The 7-Seg LED displays the 3-digit error codes one digit
at a time. The remote controller (if installed) displays the
whole 3-digit error code at once. When the right and/or left
combustion section has an error code, the red lamp next to
the 7-Seg LED on the central computer board will flash to
indicate which combustion section has the error code. Refer
to the above picture.
Example:
If your unit has the “321” error code (inlet thermistor),

- The 7-Seg LED, will flash the 3-digit error code one digit
at a time. The 7-Seg LED will display “3”...“2”... “1”, and
then repeat the 3 digits.
The remote controller, however, will display “321” on its
screen, in its entirety.