Mounting the 3g hd-sdi 101, Tabletop placement, Ul guidelines for rack mounting – Extron Electronics 3G HD-SDI 101 User Guide User Manual

Page 7: Rack mounting

Advertising
background image

3G HD-SDI 101 • Installation and Operation

3

Mounting the 3G HD-SDI 101

The small size of this extender allows it to be mounted on a

tabletop, on a rack, or under furniture.

N

The 3G HD-SDI 101 is designed be placed at the end of a

long cable run and close to the display device.

Tabletop placement

Attach the four included rubber feet to the bottom of the unit

and place it in any convenient location.

Rack Mounting

UL guidelines for rack mounting

The following Underwriters Laboratories (UL) guidelines are

relevant to the safe installation of the 3G HD-SDI 101 in a rack:
1

.

Elevated operating ambient temperature —

If the unit

is installed in a closed or multi-unit rack assembly, the

operating ambient temperature of the rack environment

may be greater than room ambient temperature. Therefore,

install the equipment in an environment compatible with

the maximum ambient temperature (Tma: +122 °F, +50 ° C)

specified by Extron.

2

.

Reduced air flow —

Install the equipment in the rack

so that the equipment gets adequate air flow for safe

operation.

3

.

Mechanical loading —

Mount the equipment in the rack

so that uneven mechanical loading does not create a

hazardous condition.

4

.

Circuit overloading —

Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Give appropriate consideration to the

equipment nameplate ratings.

5

.

Reliable earthing (grounding) —

Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (such as power strips).

Advertising