Cc 300, cc 600, cc 800, tle, tlp installation, Cc 300, cc 600, cc 800, Tle, tlp installation – Extron Electronics Cable Retraction System User Guide User Manual

Page 20

Advertising
background image

Cable Retraction System • Installation

14

CC 300, CC 600, CC 800, TLE, TLP Installation

The enclosure must be installed and properly configured before beginning the retraction
system installation.

1.

With the cable release buttons against the enclosure wall, install the retraction system
by pushing the system up and into the enclosure (see figure 13).

2.

With the retraction system against the sidewall, press the mounting bolt through the
second hole from the edge of the Cable Cubby enclosure, through the retraction
system, then out the other side of the enclosure.

3.

Thread the nut on the bolt and tighten.

ATTENTION: Do not overtighten the enclosure mounting bolt. It only needs

to be snug. Overtightening could deform the retractor housing and cause
misalignment of the pulley wheels resulting in malfunction.

2

1

3

Figure 13.

Retraction System Installation

4.

Connect the retraction system cables and other AAP cables (if installed).

5.

If horizontally mounting the retractors, proceed to

Horizontal Bracket Mounting

on

page 15.
For vertical and angular mounting, see

Locking Screw (Optional)

on page 17 for

final installation details.

Advertising