TP cable termination

Figure 7 details the recommended termination of TP cables with RJ-45 connectors in
accordance with either the TIA/EIA T 568A or the TIA/EIA T 568B wiring standard.

5

Pin

1

2
3

6
7
8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

Wire color

White-green
Green
White-orange

White-blue
Orange
White-brown

Brown

TIA/EIA T

568 A

TIA/EIA T

568 B

Blue

Side

12345678

Insert

Twisted

Pair Wires

Pins:

RJ-45

Connector

Figure 7.

TP Cable Termination

NOTES:

RJ-45 termination with CAT 5e, CAT 6, or CAT 6a cable must comply with

the TIA/EIA T 568A or TIA/EIA T 568B wiring standard for all connections.

Terminate both ends of both cables identically, in accordance with either

TIA/EIA T 568A or TIA/EIA T 568B.

Do not use Extron UTP23SF-4 Enhanced Skew-Free™ AV UTP cable or

STP201 cable to link the transmitter and receiver. The DTP DVI 301 Tx/Rx
does not work properly with these cables.

Only one cable, DTP, is necessary. The Analog Audio cable carries an

additional audio signal that is not required for system operation.

Connect transmitter DTP Out to receiver DTP In.

Connect transmitter Analog Audio Out to receiver Analog Audio In.

If necessary, check the DTP Out to DTP In cable connection as follows:

1

. Plug a cable into the DTP port on the powered unit.

2

. Connect the opposite end of the cable into the DTP port on the

unpowered unit.

If the DTP Link LED and the Power LED on the unpowered unit are lit, the

connection is correct.

DTP HDMI 301 • Installation and Operation