f

Ethernet connector (RJ-45) — Connect one end of a Category (CAT) 5e or higher

cable, terminated with RJ-45 connectors, to the FPC 5500 via this RJ-45 Ethernet
connector.

NOTE: The FPC 5500 ships with a 10-foot crossover CAT 5e cable.

For direct connection to the Ethernet port — Plug the RJ-45 connector on the
opposite end of the CAT 5e or higher cable directly into Ethernet port (BME 0 on a
Matrix 12800 system) (see figure

8). Wire the CAT 5e or higher cable as a crossover

cable (see ”

Cabling and RJ-45 connector wiring

” on page 10).

FPC 5500

Matrix 12800

Crossover Cable

MATRIX 12800

WIDEBAND VIDEO

RESET

MATRIX SWITCHER CONTROLLER

FPC 5500

Figure 8.

Connecting the FPC Directly to a Matrix Switcher

For Ethernet connection to the matrix system — Plug the RJ-45 connector on the
opposite end of the CAT 5e or higher cable into the Ethernet LAN on which the matrix
system (BME 0 on a Matrix 12800 system) resides (see figure

9). Wire the CAT 5e or

higher cable as a patch (straight) cable (see ”

Cabling and RJ-45 connector wiring

on page 10).

FPC 5500

Matrix 12800

Laptop

Patch Cable

Patch Cable

MATRIX 12800

WIDEBAND VIDEO

RESET

MATRIX SWITCHER CONTROLLER

FPC 5500

Ethernet

Figure 9.

Connecting the FPC through a LAN

g

Audio (Line-Out) — This connector is not used with the FPC 5500.