Selecting the RS-232 or RS-422 Protocol and Baud Rate

The HDXP switchers can support either RS-232 or RS-422 serial communication
protocol, and operate at 9600, 19200, 38400, and 115200 baud rates. The settings of
these variables can be viewed and changed from the front panel.

NOTE: This information applies to only the rear panel Remote RS232/RS422 port.

The front panel Config port is RS-232 only; RS-422 cannot be selected for it.

View and configure the serial communications settings as follows:

1.

To enter serial port configuration mode, simultaneously press and

hold all Control

buttons (Enter, Preset, View

<

, and Esc

>

) until all buttons light (approximately

2 seconds).

C O N T R O L

PRESET

ENTER

I / O

MATRIX PREVIEW

C O N T R O L

PRESET

ENTER

ESC

VIEW

ESC

VIEW

2 seconds

All Control buttons light with one flashing.
Both I/O buttons light with one flashing.
The flashing Control button indicates the

baud rate as follows:

Enter — 9600

Preset — 19200

View

<

— 38400

Esc

>

— 115200

Press and

hold the Enter, Preset,

View

<

, and Esc

>

buttons

.

= Blinking button

The flashing I/O button indicates the

protocol as follows:

Matrix — RS-232 Preview — RS-422/RS-485

In this example, the port is set to RS-232 at 9600 baud.

Figure 58.

Enabling Serial Port Configuration Mode

2.

Release the Control buttons.

3.

To change a value, press and release the button that relates to the desired value.
Baud rate:

Enter selects 9600 baud.

Preset selects 19200.

View

<

selects 38400 baud.

Esc

>

selects 115200 baud.

Protocol:

Matrix selects RS-232

Preview selects RS-422.

C O N T R O L

PRESET

ENTER

I / O

MATRIX PREVIEW

ESC

VIEW

= Blinking button

Press and release the button(s) to configure the port as
follows:
Baud rate:
Enter — 9600

Preset — 19200

View

<

— 38400

Esc

>

— 115200

Serial protocol:
Matrix — RS-232

Preview — RS-422/RS-485

The selected buttons blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

Figure 59.

Selecting RS-232 or RS-422 and the Baud Rate