Communication software, Setting up internet communication, Ethernet connection – Extron Electronics MGP 462xi Series User Manual

Page 55: Default address, Communication software, Preliminar y

Advertising
background image

4-3

MGP Series • Software Configuration and Control

PRELIMINAR

Y

N

The cables used to connect the RS-232/422 port to a computer or control system

may need to be modified by removing pins or cutting wires. If unneeded pins are
connected, the processor may hang up.

Communication software

There are several programs that enable you to connect the MGP to a computer

or control device via the RS-232/422 interface, and to enter commands.

HyperTerminal for Windows is one such program that is commonly used on PCs.

In addition, the MGP has a Windows-based control software program, discussed

later in this chapter, that is available through the RS-232/422 port, the front panel

Config port, or via Ethernet. (See the MGP software’s help file for information on

using the software to configure the MGP.)
For any program that you use, set up communication using the following protocol:
Baud rate: 9600

Stop Bits: 1

Data bits: 8

Flow Control: None

Parity: None

Setting Up Internet Communication

The rear panel Ethernet connector on the MGP can be connected to an Ethernet

LAN or WAN. This connection makes SIS control of the MGP possible using a

computer connected to the same LAN or WAN.

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

RJ-45

Connector

Insert Twisted

Pair Wires

12345678

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

White-orange

Orange

Orange

White-green

White-green

Blue

White-blue
Green

Green

White-brown

Brown

RJ-45 connector pinout table

Ethernet connection

The cable can be terminated as either a patch cable or a crossover cable (figure 4-3)

and must be properly terminated for your application:

Patch (straight) cable — Connection of the ISS to an Ethernet hub, router, or

switch that also hosts a controlling computer

Crossover cable — Direct connection between the ISS and a computer

Default address

To access the MGP via the LAN port, you need the MGP’s IP address. If the

address has been changed to an address comprised of words and characters,

you can get the actual numeric IP address using the front panel (see “

Comm./IP

Configuration Menu

” in chapter 3, “Operation”). If the address has not been

changed, the factory-specified default is 192.168.254.254.