Mls 608 d series • setup guide (continued), Step 4 — connect outputs from mtp/hdmi u r, Step 5 — connect control devices – Extron Electronics MLS 608 D Series Setup Guide User Manual

Page 4: Step 6 — connect power

Advertising
background image

4

MLS 608 D Series • Setup Guide (Continued)

RGB

VID

Y/C

B-Y

Y

R-Y

ANALOG OUTPUTS

RS-232

Tx Rx

SPARE

1

MONO AUDIO

2

Component Video –
Connect to these 3 BNCs.

Composite Video –
Connect to this BNC.

RGBHV and RGBS –
Connect to this VGA
connector.

S-video – Connect to
this mini DIN connector.

Mono Audio – Connect
to this captive screw
connector.

L

MONO A

UDI
O

R

L

MONO A

UDI
O

R

Unbalanced Output

Balanced Output

Mono output 1-

Sleeve(s)

Mono output 1+

Mono output 2+

Mono output 2-

Sleeve(s)

Mono output 1

Mono output 2

NO GROUND.

NO GROUND.

Wire the audio connector as shown above.

RS-232 Control (Analog Side) –
NOT USED IN THE MLS 608 D SYSTEM.

Do not tin
the wires!

Step 4 — Connect Outputs from MTP/HDMI U R

Digital video — Connect a display to the HDMI
connector for digital video output.
Analog video — Connect the analog outputs as
shown at right.
Audio — Connect a suitable audio device, such as
powered speakers, to the 5-pole captive screw audio
output connector for a balanced or unbalanced, dual
mono audio signal. Wire connector as shown at right.


NOTE:

The audio signal is detected on the MTP input and then is distributed to the audio connector for output.

RS-232 control (digital side) — Connect a serial communications port on a display device to the
3.5 mm, 3-pole captive screw connector (labeled RS-232 pass-thru) for pass-through RS-232
bidirectional communication. Wire the connector as shown at right.

NOTE:

The RS-232 control port on the analog side is not used in the MLS 608 D system.

Step 5 — Connect Control Devices

RS-232 control — Connect a host computer or control system (such
as an optional MLC 226) to the 5-pin connector (see

m

on page 1)

for MLS switcher configuration and control via RS-232 using
Extron software or Simple Instruction Set (SIS) commands.
Wire the MLS as shown at right.

NOTE:

This serial port is independent of the front panel
configuration port. Both may be used for MLS control.

RS-232 protocol (default values):
• 38400 baud •1 stop bit • no parity • 8 data bits • no flow control

NOTE:

The ‘+’ and ‘-’ pins on this connector can be used to
power a controller, for example an MLC 226 IP and a
connected IRCM-DV+.

RS-232 Insert port (optional) — Connect an optional control
device (for example an MLC 226 IP via the RS-232 display control port)
to the 5-pin connector (see

n

on page 1) for pass through RS-232

communication to a connected projector or display device.
Wire the connection as shown at right.

Step 6 — Connect Power

MLS 608 D — Plug in a standard IEC power cord from a 110 - 240 VAC, 50 - 60 Hz power
source into the receptacle (see

a

on page 1).

Optional — Connect the 2-pole power connector (see

e

on page 1) for remote power to an

MTP transmitter or receiver. Wire the connection as shown at right.
Optional — Connect the “+” and ”-” pins on the RS-232 connector (see

m

on page 1) for remote

power to an optional controller (such as the MLC 226). See second note, step 4 above

.

MTP/HDMI U R — Connect the 2-pole 3.5 millimeter captive screw connector from the 12 VDC,
1.0 A external power supply (provided) to this receptacle on the rear panel, or connect to the 2-pole
power connector (see

e

on page 1) on the MLS 608 D. Wire connector as shown at right.

For both devices, when power is applied the front panel power LED lights.

RS-232

Host

Tx Rx

MLS 608 D
rear panel
RS-232 Host
port

MLC's
MLS and
Power
ports

A B C D E

DISPLAY

RS-232/IR

RS-232 12V

CM/IR/SCP

A B C D E

MLS PWR

A B

Tx/I

R

Rx

GR

O

UND

PWR SN

S

GR

O

UND

+12V OU

T

Rx

Tx

GR

OUND

GR

OUND

+12V IN

+12V OU

T

GR

OUND

CONT MO

D

IR IN

SCP CO

M

NORMALLY OPEN

1 2

COMMON

COMMON

COMMON

GR

OUND

Tx/IR

Tx/IR

Tx/IR

GR

OUND

GR

OUND

A

RELAYS

IR/SERIAL OUT

3 4

B

5 6

C

A

B

C

NOTE: If you use cable that has

a drain wire, tie the drain wire
to ground at both ends.

NOTE:

You must connect a ground

wire between the MLC and MLS.

MLS 608 D SA
Rear Panel

MLC 226 IP
Bottom Panel

RS-232 12V

MLS PWR

A B

Rx

Tx

GR

OUND

GR

OUND

+12V IN

Ground ( )

Transmit (Tx)

B Receive (Rx)

A

Transmit (Tx)

Receive (Rx)

B

A

Ground ( )

+12 VDC input

1

BUFFERED OUTPUT

MTP

+

AUDIO

+12 V OUT

PWR OUT=

12W

2

3

6

L

R

1

L

R

2

L

R

3

L

R

5

L

R

7

L

R

8

1

2

1

2

MIC/LINE

+ 48V

1

2

L

R

L

R

Tx

+12V

Rx

8

4 (MTP)

CONFIGURABLE ANALOG INPUTS

AUDIO INPUTS

AUDIO OUTPUTS

RS-232

HOST

PWR OUT = 7.2W

DIGITAL OUTPUT

VIDEO + RS-232

ANALOG OUTPUT

DIGITAL INPUTS

5

7

L

R

6

Tx

N/

A

N/

A

Rx

RS-232 INSERT

MLS 608 D SA

100-240V 50/60 Hz

1.2A MAX

1

2

4/8 OHM - 20W x 2

MLC 226 Display port

DISPLAY

RS-232/IR

Tx/IR

Rx

GR

OUND

PWR SNS

GR

OUND

+12V OUT

Ground ( )

Receive (Rx)

Transmit (Tx)

RS-232 INSERT

MLS 608 D rear panel
RS-232 Insert port

Tx
Rx

N/A

N/A

RS-232 Device Pins

MTP/HDMI

RS-232

Pass-thru

port

Rx

Ground

Tx

Rx

Tx

Power Supply

Output Cord

2-pole Captive

Screw

Connector

SECTION A–A

Ridges

Smooth

A

A

Tie Wrap

3

Advertising