Extron Electronics MSX1616HR User Manual

Page 34

Advertising
background image

32

MSX1616 OPERATION MANUAL - v1.0 5/8/02

2002 - INLINE, INC.

COMMAND

DESCRIPTION

[VINiix]

Increments/decrements input volume level for a specific
input.

Where

o

ii = 01 – 16 for input

o

x = + (plus sign) to increment input
volume

o

x = - (minus sign) to decrement input
volume

o

x = @ to return input volume to factory
default (0 dB)

o

x = ? to request current volume level

[VINiixxx]

Increments/decrements input volume level for a specific
input.

Where

o

oo = 01 – 16 for input

o

xxx = -640 - 0

Note: 0 equals max (+0.0 db), -640 equals minimum
(-55.0 dB)

[LMUTE,a,b,c,d,e,f,g,h,I,j,k,l,m,n
,o,p,
]

Preload mute state for all outputs.
Must send a [TAKE] command to execute changes.

Where

o

a = 0 to disable, 1 to enable for output 1

o

b = 0 to disable, 1 to enable for output 2

o

c = 0 to disable, 1 to enable for output 3

o

d = 0 to disable, 1 to enable for output 4

o

e = 0 to disable, 1 to enable for output 5

o

f = 0 to disable, 1 to enable for output 6

o

g = 0 to disable, 1 to enable for output 7

o

h = 0 to disable, 1 to enable for output 8

o

etc.

[LMUTE,?]

Queries all LMUTE commands.

[LVOL,aaa,bbb,ccc,ddd,ee,efff,gg
g,hhh,iii,jjj,kk,lll,mmm,nnn,ooo,p
pp
]

Preload output volume level for all outputs.
Must send a [TAKE] command to execute changes.

Where

o

aaa = -550 to 90 for output 1

o

bbb = -550 to 90 for output 2

o

ccc = -550 to 90 for output 3

o

ddd = -550 to 90 for output 4

o

eee = -550 to 90 for output 5

o

fff = -550 to 90 for output 6

o

ggg = -550 to 90 for output 7

o

hhh = -550 to 90 for output 8

o

etc.

Note: Level is set in .5 dB steps. For example, –23.5dB
is entered as -235

[LVOL,?]

Queries any previously loaded LVOL commands.

Advertising
This manual is related to the following products: