Serial bridging, Hardware connection, Serial bridge configuration – Extron Electronics IPL 250 Reference Manual User Manual

Page 41: Serial bridging -15

Advertising
background image

3-15

IPL 250 • Software-based Configuration and Control

Serial bridging

Serial bridging mode creates a virtual serial connection (a “bridge”) between two

IPL units allowing serial data to be passed over a shared LAN to devices connected

via the IPLs’ COM ports. To use serial bridging, two IPL devices (one local and

one remote) must be enabled to communicate with each other, providing PC,

touchpanel, or controller access to a remote A/V device.

Hardware connection

To set up the hardware for serial bridging:

1.

Verify that the protocol (baud rate, data bits, stop bits, parity) is identical for

both serial ports that will be “bridged” (one port on each IPL unit).

2.

For IPL unit 1 (the remote device), connect a serial cable to an A/V device

(e.g., a display or projector).

3.

Connect that same remote IPL (1) to the LAN.

COM

3

LA

N

UID# 093012052

PO

WE

R

12V

.5A MA

X

COM

2

COM

1

COM

2

RS-232

Plasma Display

Unit 1
(Remote)

Unit 2
(Local)

Extron

IPL T S4

Ethernet Control
Interface

Ethernet

INPU

T

LA

N

POWE

R

12V
500m

A

MAX

1

2

3

4

COM

3

IR

3

S

G

S

G

TX

RX

4

RELA

Y

3

4

COM1

TX

RX

RTS CT

S

COM

2

IR

1

S

G

S

G

TX

RX

2

RELA

Y

1

2

Extron

IPL 250

IP Link

®

Ethernet

Control Processor

Remote User Control &
Administrator Monitoring

Ethernet

RS-232

TCP/IP

Network

Connections for serial bridging

4.

For IPL unit 2 (the local device), make a serial connection to the PC or

controller or touchpanel that will control the remote A/V device.

5.

On the same device (2), follow the step 2 instructions.

You are now ready to configure IPL unit 2 for serial bridging mode.

Serial bridge configuration

To allow both IPL units to communicate together, you must configure unit 2 to

communicate with unit 1.

N

If a serial (RS-232) driver was previously loaded (via Global Configurator) onto

the IPL unit, serial bridging disables it.

To configure unit 2 to communicate with unit 1:

1.

Enter the IP address of unit 2 in the Internet browser’s Address field at the

top of the screen, and press the Enter key. The System Status page opens,

showing the current IP and serial port settings of IPL 250 unit 2.

2.

Access the Web server port setting screen by clicking the Configuration tab,

then the Port Settings link on the left side of the window. The Port Settings

page appears, as shown in the following figure.