Power supply wiring, Ew connector (see – Extron Electronics MTP DA8 User Guide User Manual

Page 13

Advertising
background image

NOTES:

The MTP DA output does not provide any pre-peaking control. The total

recommended distance for a complex system with multiple DA outputs is
the same as for a simple system with a single transmitter and receiver.

See the recommended transmission ranges in the table on page 2. The
recommendations in the table apply to a complete transmission system,
which can include a single transmitter, DA, and multiple receivers or a
complex system including multiple daisy-chained receivers.

d

Output Mute connections — The Output Mute connector provides a way to mute

(blank) any or all TP outputs. Each numbered pin of the captive screw connector is
assigned to one of the DA outputs. Pin A is assigned to all DA outputs (see

figure

4).

When you short and latch a numbered pin or pins to ground, the DA mutes the
associated outputs.

1 2 3 4 5 6 7 8 A

MTP DA8

Output Mute Connector

1 2 3 4 A

MTP DA4

Output Mute Connector

Pin

Contact

Closure

Function

1

Out #1

Mute output #1

2

Out #2

Mute output #2

3

Out #3

Mute output #3

4

Out #4

Mute output #4

5

Out #5

Mute output #5

6

Out #6

Mute output #6

7

Out #7

Mute output #7

8

Out #8

Mute output #8

A

Out All

Mute all outputs

Gnd

Ground

Figure 4.

Mute Connector and Pinout

Power Supply Wiring

Figure

5 shows how to wire the power connector (see the caution, attention, and notes on

the next page before wiring the power connector).

SECTION A–A

A

A

Power Supply

Output

Cord

2-Pole Captive Screw
Connector

Ridges

Smooth

Tie Wrap

3/16”

(5 mm) Max.

Figure 5.

Power Connector Wiring

MTP DA4 and MTP DA8 • Installation and Operation