Rs-232 setup, Selecting transition effects, Selecting wipe, pip, and title effects – Extron Electronics RCP 2000 with ISS 506 Support Setup Guide User Manual

Page 2

Advertising
background image

RCP 2000 with ISS 506 Support • Setup Guide

2

RCP 2000 with ISS 506 Support Setup Guide (cont'd)

RS-232 Setup

To configure an RS-232 connection to the switcher,
1

.

Plug the supplied 12' RS-232 cable into the RCP's rear panel To Switcher port and the switcher's RS-232/422 port.

2

.

Press and hold the Color/Tint, Cont/Bright, Size, and Center buttons simultaneously until the Cut button lights and

the MAC address appears in the LCD window.

3

.

Press Cut two times, until the switcher IP address is displayed in the LCD window. The Color/Tint button flashes.

4

.

Set the switcher's IP address to 000.000.000.000 as follows:

a

. Press one of the picture control buttons to access the desired octet of the switcher's IP address. Access the address

blocks as follows:

Select

1st octet Select 2nd octet Select 3rd octet Select 4th octet

b

. When the desired octet is blinking in the LCD window, rotate the H knob all the way to

the left to set the address block to 000.

c

. Repeat steps a and b as needed for each address block that needs to be set to 000.

5

.

If you need to change the switcher's baud rate, press Cut repeatedly until the Sw Baud screen appears.

Rotate the H knob to set the switcher's baud rate.

6

.

Press Detail to exit the setup menu.

Selecting Transition Effects

Selecting wipe, PIP, and title effects

To select a wipe, PIP, or title effect,
1.

Press and hold the Wipe button.

2.

While holding the Wipe button, press the Dissolve

button repeatedly to cycle through the Wipe, Pip, and

Title menus.

For Title,

press Wipe + Dissolve until Title Lvl is

displayed on the LCD screen, then skip to step 4.

3.

When the desired function (Wipe or Pip) is displayed

in the LCD window, continue to hold down the Wipe

button while turning the Adjust knob to select the

number of the desired sub-effect (02 through 25 for

Wipe; 01 through 25 for PIP). See the label in the upper-

right corner of the RCP front panel for a list of available

effects.

N

You can not select a cut sub-effect while in Wipe or

PIP mode. To perform a cut in these modes, select the desired preview input, then press the Cut button.

4

.

Release the Wipe button (it should remain lit), and rotate the Adjust knob to select the duration of the sub-effect (0.0 to

5.0 seconds) or the intensity level (Lvl) of the preview image that will become transparent in Title mode (000 to 255).

N

If you want to control the duration of the wipe and PIP effects manually, move the T handle up or down at the desired rate.

5

.

Press the Take button to implement your effect on the selected preview input.

WIPE

DISSOLVE

Press

and hold

Press to step

through menu

+

WIPE

Hold

Rotate to

select wipe

+

ADJUST

Press

Press

ADJUST

Press

02-25

ADJUST

01-25

DISSOLVE

DISSOLVE

DISSOLVE

Wipe #03

0.5 Sec

Pip #03

0.5 Sec

Title

Lvl 15

0

Default

Cycle

WIPE

Press
and hold

ADJUST

0.0-5.0 Sec.

ADJUST

0.0-5.0 Sec.

ADJUST

0-255

WIPE

WIPE

Release

WIPE

Release

Release

COLOR

TINT

Press

CONT

BRIGHT

Press

SIZE

Press

CENTER

Press

S 000.000

I 000.000

H

Rotate to set
blinking octet to 000.

Sw Baud

9600

H

9600-115,200

Advertising