Installation, cont’d

MVX Plus 128 VGA A Matrix Switcher • Installation

2-8

PRELIMINAR

Y

Front Panel Configuration Port

MVX PLUS SERIES

VGA MATRIX SWITCHER

WITH

IP LINK™

AUDIO

VIDEO

I/O

CONTROL

ENTER

PRESET

VIEW

ESC

CONFIG

9

Figure 2-7 — Front panel configuration port

i

Configuration port — This 2.5 mm mini stereo jack serves the same serial

communications function as the rear panel Remote port, but is easier to access

than the rear port after the matrix switcher has been installed and cabled.

The optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable, part #70-335-01

(figure 2-8), can be used for this connection.

6 feet

(1.8 m)

Part #

70-335-01

5

1

9

6

Sleeve (Gnd)

Ring

Tip

9-pin D

Connection

TRS Plug

Pin 2

Computer's RX line

Tip

Pin 3

Computer's TX line

Ring

Pin 5

Computer's signal ground

Sleeve

Figure 2-8 — Optional 9-pin TRS RS-232 cable

N

This port is independent of the rear panel Remote port and is not affected by

changes to the rear panel port’s protocol. This front panel port’s protocol can be
changed, under SIS command control only. See the Command/Response table
for IP SIS commands, in chapter 4, “Programmer’s Guide”, to configure all
ports under SIS control.

N

A front panel Configuration port connection and a rear panel Remote port

connection can both be active at the same time.

The Configuration port is RS-232 only, with its default protocols as follows:
• 9600 baud

• no parity

• 8 data bits

• 1 stop bit

• no flow control

N

The maximum distances from the matrix switcher to the controlling device

can vary up to 200 feet (61 m). Factors such as cable gauge, baud rates,
environment, and output levels (from the switcher and the controlling device)
all affect transmission distance. Distances of about 50 feet (15 m) are typically
not a problem. In some cases the matrix switcher may be capable of serial
communications via RS-232 up to 250 feet (76 m) away.