Remote control, cont’d, Setup commands, Command description – Extron Electronics SWP123 User Manual

Page 32

Advertising
background image

SWP123 Presentation Switcher • Remote Control

Remote Control, cont’d

Setup commands

Use these commands to configure the switcher. If you are using a third-party
control system, you should place these commands in the start-up section of the
program.

Command

Description

Request information

[ARC]

Requests model and version information.

Reset comm port

[CPx@]

Resets the communications port to the factory default (9600
baud, 8-bit, 1 stop bit, no parity, and no flow control).

x

= 1

Query comm port

[CPx?]

Queries the communications port for current settings.

x

= 1

Configure comm port

[CPxbpsfd]

Configures the communications port for baud rate, parity,
stop bits, flow control, and duplex.

x

= 1

b

= 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600,

4 for 19200, and 5 for 38400
p

= 0 for no parity

s

= 0 for 1 stop bit

f

= 0 to disable and 1 to enable flow control (xON

xOFF)
d

= 0 for full duplex, 1 for half duplex

Factory reset

[DFLTx]

Performs a factory reset. The partial reset returns I/O
configurations, volume levels, and serial setup to factory
levels. The full reset returns all parameters (including
presets) to factory default levels.

x

= 0 for partial reset

x

= 1 for for full reset

Front panel executive mode

[FPx]

Enables or disables front panel executive mode and
requests current status.

x

= 0 to disable the front panel (executive mode)

x

= 1 to enable the front panel

x

= ? to request current state

x

= (blank) to toggle the current state

Serial response enable

[RESx]

Enables or disables serial responses from the switcher.

x

= 0 to disable

x

= 1 to enable

5-4

Advertising