Spencer VB055 Vortex Regenerative Blowers User Manual

Page 18

Advertising
background image

1188

TTrroouubbllee

PPoossssiibbllee CCaauussee

CCoorrrreeccttiivvee AAccttiioonn

BBlloowweerr DDooeess NNoott TTuurrnn

aanndd tthheerree iiss --

AA HHuum

mm

miinngg SSoouunndd

– One phase of power line disconnected

Connect power leads properly

– One phase of stator line open

Contact factory

– Bearing(s) defective

Change defective bearing(s)

– Impeller jammed by foreign material

Clean impeller

– Impeller jammed against casing or

Adjust gap

side cover

– Rubbing of rotor core and stator core

Contact factory

– Capacitor open (single-phase models)

Change capacitor

NNoo SSoouunndd

– Two phases of power line disconnected

Connect power leads properly

– Two phases of stator winding open

Contact factory

– Faulty switch connection

Change switch

– Fuse blown

Change fuse

BBlloowweerr TTuurrnnss,, bbuutt --

FFuussee BBlloowwss

– Fuse capacity insufficient, wiring fault

Inspect wiring

– Short circuit

Repair

– Terminals shorted

Improve insulation and check

connections

– Excessive load

Increase air flow

O

Ovveerrhheeaattss oorr TThheerrm

maall

PPrrootteeccttoorr AAccttiivvaatteess

– Power source unbalance; possible

Check voltage; phases must be

voltage drop

balanced within 5% and voltage must

be within 10% of rated

– Operating in single-phase condition

Check connections

– Excessive friction due to defective bearings

Replace bearings

– Impeller contaminated by foreign material

Clean impeller

– Impeller rubbing against casing or side cover

Adjust gap

– Operation at less than minimum rated flow

Increase air flow

– Inlet air filter clogged

Clear or replace element

M

Maakkeess AAbbnnoorrm

maall oorr

EExxcceessssiivvee SSoouunndd

– Impeller rubbing against casing or side cover

Adjust gap

– Impeller rubbed by foreign material

Clean impeller

– Bearing(s) defective

Replace bearings

– There is a leak or air passages are clogged

Repair or clean

– Loose cap screw

Tighten screw

– Air channel noise absorber foam damaged

Replace absorbers

VVII.. TTrroouubblleesshhoooottiinngg G

Guuiiddee

TThhee SSppeenncceerr TTuurrbbiinnee CCoom

mppaannyy

600 Day Hill Road, Windsor, CT 06095

TEL 800-232-4321

860-688-8361

www.spencerturbine.com

Advertising
This manual is related to the following products: