2. For models VB001, VB002 and VB003, gap clearance

between impeller and unibody case should be

checked around entire periphery of the impeller in

accordance with Item 18, impeller to case gap specifi-

cation prior to securing impeller.

3 On models VB004 thru VB110 remove Item 23 Plug

located on bottom of the case and check impeller gap

with a feeler gauge. Remove impeller and adjust

shims to meet gap specification. With adjustments and

gap check complete, replace plug tightly to prevent air

leakage.

4. Fasten impellers using lockwashers and locknuts.

Torgue locknut to recommended torque values in

Table 3. Bend a lockwasher tab down into a lockwash-

er slot.

5. Reattach the impeller cover.

VV.. VVoorrtteexx BBlloowweerr DDaattaa

Pages 7 through 17 present information about the

various blower models. This information is important

in understanding your blowerʼs performance, in using

the blower in the proper operating range, and in ordering

parts that might be needed.

AA.. AAsssseem

mbbllyy DDiiaaggrraam

mss

At the top of each page is an assembly diagram of the

unit. Items are identified by circled numbers around the

diagram. Above each diagram is the gap specification.

BB.. PPaarrttss LLiissttss

At the lower left of each diagram is a table giving the

item number (shown on the Assembly Diagram), the

Part No. for that item and the corresponding part

description. In ordering parts, provide the model

number, the part number and the description.

CC.. PPeerrffoorrm

maannccee CCuurrvveess

At the lower right of each diagram are performance

curves for 50Hz and 60Hz operation. The curves

present the following information:

The upper line of each curve is pressure performance

while the lower line is vacuum performance. The

dashed portion at the left end of some of the curves

indicates an intermittent-only operating area. See

O

Oppeerraattiioonn Section on page 5.
DD.. EEssttiim

maatteedd AAccoouussttiiccaall NNooiissee LLeevveell aatt 11..55M

M,, 6600HHzz

M

Mooddeell

ddbbaa

VB001S

62

VB001

61

VB002S

61

VB002

61

VB003S

66

VB003

66

VB004S

63

VB004

63

VB007S

70

VB007

64

VB019S

70

VB019

73

VB030S

71

VB030

73

VB037S

74

VB037

76

VB055

82

VB075

81

VB110

80

TTaabbllee 33 LLoocckknnuutt TToorrqquuee

TThhee SSppeenncceerr TTuurrbbiinnee CCoom

mppaannyy

600 Day Hill Road, Windsor, CT 06095

TEL 800-232-4321

860-688-8361

www.spencerturbine.com

VB001, VB001S, VB002

VB002S, VB003, VB003S

VB004, VB004S

VB007, VB007S

VB019, VB019S

VB030, VB030S

VB037, VB037S

VB055

VB075

VB110

22

31

36

36

44

44

77

90

90

CCaattaalloogg NNoo..

RReeccoom

mm

meennddeedd

TToorrqquuee ((FFtt--LLbb))

Advertising
This manual is related to the following products: