General information – Liberty Pumps LSGX200-Series Omnivore User Manual

Page 3

Advertising
background image

©Copyright 2012 Liberty Pumps Inc. All rights reserved

- 3 -

1.

Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper

performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.

Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.

The electrical connections and wiring for a pump installation should only be made by qualified personnel.

This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric

shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

DO NOT bypass grounding wires or remove ground prong from attachment plugs.

DO NOT use an extension cord.

This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly

sized for the voltage and amperage requirements of the pump, as noted on the nameplate.

The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level

to minimize possible hazards from flood conditions.

The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International

Plumbing Code, as well as all applicable local codes and ordinances.

Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective

clothing when working on a used pump or piping.

Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are poisonous.

Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.

DO NOT use this product for flammable or corrosive liquid.

DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming

pools, fountains, etc.)

NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and

damage pump components, potentially causing product malfunction or failure.

Do not use these pumps in water over 140

F.

The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals a

malfunction of the system, to reduce the potential for property damage.

Note: Manual models (“M”

suffix), require a separate

approved pump control device or

panel for automatic operation.

Operation of these models will be

according to the control selected.

Make

sure

the

electrical

specifications of the control

selected properly match the

electrical specifications of the

pump. Always refer to control

panel instructions for proper

installation.

Models with ("M-C" suffix) require

external capacitors and relay.

(Order kit K001316)

start cap - 200-240, 220V

or 216 – 259 uf, 250V

run cap - 50 uf, 370V

Mars Potential Relay 19551 (#551)

pick up 244V – 270V

drop out of 40V-90V

Model

HP

Volts

Pha

se

Full Load

Amps

FNPT

Discharge

Automatic or

Manual*

LSG202A

2

208/230

1

15

1.25”

Automatic

LSG202M

2

208/230

1

15

1.25”

Manual

LSG202M-C

2

208/230

1

15

1.25”

Manual

LSG203M

2

208/230

3

10.6

1.25”

Manual

LSG204M

2

440-480

3

5.3

1.25”

Manual

LSG205M

2

575

3

4.9

1.25”

Manual

LSGX202A

2

208-230

1

15

1.25”

Automatic

LSGX202M

2

208-230

1

15

1.25”

Manual

LSGX202M-C

2

208-230

1

15

1.25”

Manual

LSGX203M

2

208/230

3

10.6

1.25”

Manual

LSGX204M

2

440-480

3

5.3

1.25”

Manual

LSGX205M

2

575

3

4.9

1.25”

Manual

General Information