Malfunctions: Causes and elimination

8

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Machine is
switched off
by the motor
protection
switch

Mains voltage/ Frequency
does not correspond with the
motor data

Check by qualifi ed electrician

Section 5.5

Connection to motor terminal
board is not correct

Motor protection switch is not
set correctly

Motor protection switch is
triggered too quickly

Use a motor protection switch with an
overload-dependent delayed switch
off that takes into consideration the
short term excess current at start up
(version with short circuit and over-
load trigger as per VDE 0660 Part 2
orIEC 947-4)

Blower operates without con-
nection to a system

Connect system

Section 5.3

Insuffi cient
suction or
pressure ca-
pacity

Blower selected was too small

If available use a bigger blower

Data sheets
D 701 / D 702

Lines are too long or too nar-
row

Check the hose or the pipe

Section 5.3

Machine or system leaking

Check the pipework and screw con-
nections for leaks and to ensure that
they are fi rmly seated

Section 7.2

Machine gets
too hot

Ambient or intake temperature
is too high

Ensure it is being used properly

Section 2.3

Blower sucks too little air

Check the rotation direction resp. cross
sections of the pipes

Section 6.1.1
Section 5.3

Cooling air supply is obstruct-
ed

Check environmental conditions

Section 5.1

Clean ventilation slots

Section 7.2

Solenoid
valve does
not work

The incoming voltage and fre-
quency does not correspond
with the information on the
solenoid valve

Check the incoming voltage and fre-
quency

Section 5.4

Valve is contaminated

Dismantle and clean

Section 7.2

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.