Smart Fan Mode Configuration (Manual RPM Mode)
Options summary:
Manual Duty Mode
Auto RPM Mode
Fan 1 Smart Fan Control
Auto Duty-Cycle Mode Default
Smart Fan Mode Select
Temperature 1
60
Default
Temperature 2
50
Default
Temperature 3
40
Default
Temperature 4
30
Default
Duty Cycle 1
85
Default
Duty Cycle 2
70
Default
Duty Cycle 3
60
Default
Duty Cycle 4
50
Default
Auto fan speed control. Fan speed will follow different temperature by different duty
cycle 1-100.
Manual RPM Mode
2000
Default
Manual mode fan control, user can write expected RPM count 500-10000
Manual Duty Mode
60
Default
Manual mode fan control, user can write expected duty cycle (PWM fan type)1-100
Chapter 3 AMI BIOS Setup 3-26