Hardware Monitor

FAN2 Configuration
The sub-items in this menu configure available fans on the system.
SYS Smart Fan control [Auto by Duty-Cycle]
Select Smart Fan control mode. Configuration options: [Auto by RPM] [Auto by

Duty-Cycle] [Manual by RPM] [Manual by Duty-Cycle]
Target Temp. Sensor
Configuration options: [CPU Temperature] [SYS Temperature]
Temperature Bound 1~4
Input temperature setting. Input value range: [0~127]
Segment 1~5 Speed (PWM)
Input fan speed in PWM duty-cycle. Input value range: [0~100]

The following item replaces Segment 1~5 Speed (PWM) when SYS Smart Fan

Control is set to Auto by RPM.

Segment 1~5 Speed (%)
Input fan speed percentage. Input value range: [0~100]

Full Speed Count [3000]
Input fan full speed count value. Input value range: [500~15000]

Full Speed Count is only available when SYS Smart Fan Control is set to

Auto by RPM.

Manual Setting [3000]
Specify fixed RPM. Input value range: [500~15000]

Manual Setting is the only item available when SYS Smart Fan Contorl is set

to Manual by RPM.

Manual Setting [100]
Specify fixed Duty-Cycle. Input value range: [0~100]

Manual Setting is the only item available when SYS Smart Fan Contorl is set

to Manual by Duty-Cycle.