Function – AAEON HSB-800I User Manual

Page 21

Advertising
background image

H a l f - s i z e S B C

H S B - 8 0 0 I

2.7 CFD Voltage 3.3V/5V Selection (JP1)

JP1

Function

1-2 3.3V

(default)

2-3 5V

2.8 Clear CMOS (JP2)

JP2

Function

1-2 Normal

(default)

2-3 Clear

CMOS

2.9 AT/ATX Power Type Selection (JP3)

JP3

Function

1-2

ATX Power Supply (default)

Open

AT Power Supply

Note: Only AT Function w/o Backplanes.

2.10 LCD Clock and Power Selection (JP4)

JP4

Function

1-3 Normal

(default)

3-5 Inverse

2-4 +5Vlcd

4-6 +3Vlcd

(default)

2.11 Inverter Voltage Selection (JP5)

JP5

Function

1-2 +12V

2-3 +5V

(default)

Chapter 2 Quick Installation Guide

2-9

Advertising