Chapter 2 Quick Installation Guide
2-9
2.7 CFD Voltage 3.3V/5V Selection (JP1)
JP1
Function
1-2 3.3V
2-3 5V
(default)
2.8 LCD Clock and Power Selection (JP2)
JP2
Function
1-3 Normal
(default)
3-5 Inverse
2-4 +5Vlcd
4-6 +3Vlcd
(default)
2.9 Inverter Voltage Selection (JP3)
JP3
Function
1-2 +12V
(default)
2-3 +5V
2.10 Clear CMOS (JP4)
JP4
Function
1-2 Normal
(default)
2-3 Clear
CMOS
2.11 AT/ATX Power Type Selection (JP5)
JP5
Function
1-2
ATX Power Supply (default)
AT Power Supply
Note: Only AT function w/o backplane.