N/C


Note:
Issue: COM port limitation for the speed test during the communication.
Root Cause:

In serial communication, data bits received at the serial port are bundled
into a byte and transmitted into the serial port hardware buffer. From the
buffer, the byte is sent into the CPU. If a new byte arrives before the byte
in the buffer is moved into the CPU, a Hardware Overrun Error occurs.

Solution:

1. Try hardware handshaking.
2. See if the UART is an older un-buffered version or a new buffered

UART (such as a 16550A or 16750). You should use a buffered UART
for the reasons discussed above.

3. Change the Receive (Rx Trigger) buffer to 8, 4, or 1 (1 is a last resort).
4. For the product, the speed setting of Series Port (COM) is under

9600bps.