AAEON AEV-6312 User Manual
Page 38
E m b e d d e d C o n t r o l l e r
A E V - 6 3 1 2
Chapter 2 Hardware Installation
2 - 23
USetting the ACC ON/OFF Delay Time
The inner PSU of AEV-6312 provides 8 different “ACC ON Delay Time”
settings (1, 3, 5, 10, 15 20, 25, 30 seconds) and 8 different “ACC OFF Delay
Time” settings (1, 3, 5, 10, 30, 60, 120, 0 minutes). If you set the “ACC ON
Delay Time Setting” for “1 sec,” it means to power on the AEV-6312 in 1
second. If you set “ACC OFF Delay Time Setting” for “0 min,” it means to
power off the AEV-6312 immediately.
The following is the JP2 setting for ACC Power ON/OFF:
Location
JP2 Setting for
ACC ON
Specification
J2
PIN 1-6
1sec~30sec
JP2 Setting for
ACC OFF
Specification
PIN 7-12
0min~120min
Function JP2
Location
PIN
Number
Set
Time
1, 2
3, 4
5, 6
OPEN
1 sec
1, 2
ACC ON
Delay Time
setting
SHORT
3 sec