AAEON AEV-6312 User Manual
Page 41
Advertising
E m b e d d e d C o n t r o l l e r
A E V - 6 3 1 2
Chapter 2 Hardware Installation
2 - 26
7, 8
11, 12
SHORT
60 min
9, 10
11, 12
SHORT
120 min
7, 8
9, 10
11, 12
SHORT
0 min
Input Low Voltage Protection
If the input voltage is lower than the “defined input low voltage (10.3V
~10.7V @ 12V mode, 20.6V~21.4V @ 24V mode)” after 60 seconds, the
inner PSU will convey a signal to imitate to press the power button to turn
off the computer. Conversely, the ACC ignition will restart the computer if
the input voltage is over 12/24 volt.
Input Low Voltage Protection for 12V / 24V
Input Mode
Input low voltage definition
12V Mode
10.5V ± 0.2V
24V Mode
21V ± 0.4V