Meaning

AC mains supply unit (AC IN)

Contact for 230V main supply unit

Kick Start jumper (KS)

Connect the two contacts of this jumper to start the alarm centre without a 230V mains power
supply.

Battery contact (+ -)

Connecting plug from standby power supply

COMMS interface

Contact for additional transistor outputs

Reset jumper (NVM RST)

Connect the two contacts of this jumper to reset the alarm centre.

Fuses (BAT F-2A / 12VAUX
F-1A)

Always use fuses of the same type. To avoid problems, make sure there is always a good
contact between the fuse holder and the fuse.

Siren sabotage input (TR)

For sirens with their own power supply, connect this input direct to the tamper output of the
siren. Otherwise, connect the tamper contact of the siren to the loop between the TR input
and 0V. If no siren is used, connect the TR input direct to the 0V output.

Optional loudspeaker (LS)

Connect a 16 Ohm loudspeaker for internal alerts.

Local download connection
(SK1)

You can connect a local PC here. The alarm centre can be configured using the downloader
program.

Connection for the telephone
connection (RJ11 + A/B /
A1/B1)

RJ11 connection/screw connections for the telephone line

Programmable transistor output (OP).
Max. power consumption of all
transistor outputs 0.5A.

12V power supply for
components (e.g.

Tamper input for
ext. components

Alarm zones 1 – 8 for NC aöarm contact
(e.g. IR detector). No NO contacts can be
connected. Make sure alarm zones are
terminated with correct resistors. Two
different resistors, or no resistor, must be
used depending on the programming. If the
zone is used then the wire bridge should be
removed.

Sir.

ta

mper input

Opt

ional speaker

control unit

1A AUX fuse for
the power supply

2A BAT fuse for the
battery charging

AC
connectio

Kick
Star

Battery
connectio

COM
interface

NVM

EEPROM

tamper cover
contact

Local
Download
-
connectio

Connection for

telephone
connection

Programmable
floating relay
output (NC/NO) /
24VDC@1A