ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 168

Advertising
background image

64

UK

Key switch (see command)

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

073 Alarm behaviour for internal (C)

To change the alarm property for internal active (C):

1. On the control unit, enter:

073

2. The LCD display shows: 073: C = Internal

3. Via the keypad, select from the following items

and press:

0

C=Keypad
Only the control units are activated.

1

C=Internal
On alarm, the control units and the
internal alarm are activated.

2

C=Local
On alarm, the control units, the internal
alarm and the external siren are
activated.

3

C=Full
On alarm, the control units, the internal
signalling, the external sirens and the
exits are activated.

In a partitioned system

0

C=Keypad
Only the control units are activated.

1

C=Local
On alarm, the control units, the internal
alarm and external sirens are activated.

2

C=Full
Control unit + internal + external +
telephone dialler

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

075 Exit delay time internal C

To change the property of the exit delay time for internal
active C:

1. On the control unit, enter:

075

2. The LCD display shows: 075: E C=10

3. Via the keypad, select from the following items

and press:

1

Exit C=10
Exit delay time for internal active C is
10 seconds.

2

Exit C=20
Exit delay time for internal active C is
20 seconds.

3

Exit C=30
Exit delay time for internal active C is
30 seconds.

4

Exit C=45
Exit delay time for internal active C is
45 seconds.

5

Exit C=60
Exit delay time for internal active C is
60 seconds.

6

Exit C=120
Exit delay time for internal active C is
120 seconds.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer mode.

Advertising