2. FEATURES

13

2.5 Communication / Interface Options,

continued

RS-232 Connections with desktop IID:

With the desktop IID the cable connecting the computer or terminal to the UPS

is a nonstandard type.

Fig. 7

CFR-UPS RS-232 Connector

Communication Settings with IID:

Baud Rate:

300 to 9600

Parity:

None, Even, or Odd

Stop Bits:

1 or 2

Data Bits:

7 or 8

Handshaking:

RTS/CTS

Internal CFR connections

1
2 Tx
3 Rx
4
5 Gnd
6
7 RTS
8 CTS
9

RS-232 cable to

computer or terminal

For the desktop IID use a

nonstandard cable type

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

52

5. RS-232 TERMINAL COMMUNICATION

Terminal Emulation Setup

If you are using a terminal emulation software (such as PROCOMM) to

communicate with the CFR, use the following setup:

Emulation Type:

VT100 or compatible

Duplex Mode:

Half Duplex

Xon/Xoff Flow Control:

SID: ON, IID: OFF

RTS/CTS Flow Control:

SID: OFF, IID: ON

Line Wrap:

ON

Screen Scroll:

ON

CR Translation:

CR

Back-Space:

N/A (See NOTE 1)

Break Length:

N/A

Inquiry:

N/A

NOTE: Back-Space and Delete characters are ignored by the
CFR. In the event of an incorrectly typed command, you should

press Enter and type the command again.

5.13 RS-232 Terminal Setup

RS-232 Cable Diagrams

The RS-232 port on the CFR follows the Data Communication Equipment (DCE)

pinout. To connect this port to a terminal or a host computer (which uses a DTE
pinout) you need a standard off-the-shelf (straight through) RS-232 cable. Depending
on your computer, you need a “

9 to 9 serial cable” or a “9 to 25 serial cable”.

However, if you decide to make you own cable, see Figures 6-7. This Figure shows
the cable that works with both SID and IID. If your CFR has a SID interface, then you
do not have to wire up the RTS and CTS signals.

1

2 - RxD

3 - TxD
4
5 - GND

6
7 - CTS
8 - RTS

9

1

2 - TxD

3 - RxD
4 - RTS
5 - CTS

6
7 - GND
8

9

24

25

1

2 - TxD

3 - RxD
4
5 - GND

6
7 - CTS
8 - RTS

9

1

2 - RxD

3 - TxD
4
5 - GND

6
7 - RTS
8 - CTS

9

To IBM-PC
Serial Port

To CFR RS-232

Port

DE-9
Male

To CFR RS-232

Port

To IBM-PC
Serial Port

DE-9 Male to DE-9 Female

DE-9 Male to DE-25 Female

Fig. 33

RS-232 Connector Cable Wiring

DE-25

Female

(DTE)

DE-9
Male

DE-9

Female

(DTE)